Connection Plan for the Alarm Relay

BUZZER

5

BLK

 

 

RED +12V

 

 

 

 

 

ALTERNATIVE

BLK

RED

 

 

1 2 3

 

 

 

External

5

 

+12 V

 

 

 

 

 

 

4

5

 

alarm

 

 

 

 

 

 

 

 

 

86

87 ALARM

 

 

 

6

7

 

 

 

 

 

 

 

85

RELAY

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

+12 V

RED

RED

+12 V

 

 

 

 

 

 

 

 

 

JUNCTION BOX TERMINAL

ALTERNATIVE

BLK

BLK

 

 

5

 

 

86

85

+12 V RED

87ALARM

30RELAY

+12 V BLK

Connection Plan for the Emergency Switch

1

2

3

4 5 6

 

 

 

 

 

7

EMERGENCY

SWITCH

JUNCTION BOX TERMINAL

To install the cable, carry out the following steps.

1.Connect the stripped lead of the fuse holder cable only to an ignition switched terminal of the fuse block. Use the supplied terminal or any other suitable terminal.

2.Mount the fuse holder using the mounting hole, and dress wires as required.

3.Cut the thin cable to the required length, crimp the supplied red lead to the stripped lead of the thin cable, and connect it to the blue terminal of the fuse holder cable.

4.Connect the other end of the ignition sense thin cable to pin 4 of the junction box terminal.

5.Insert the provided fuse into the fuse holder and close the cover.

PIN 4: If the ignition line is not used, it needs to be grounded. Interference can cause radio to hang.