1.The system fails to find the CP-132U Series board!

Windows 95/98

This section is specifically for troubleshooting under Windows 95/98. For general problems and solutions, see the previous section, “General Troubleshooting.”

1.The system fails to find the CP-132U Series board!

!The board(s) is(are) not plugged properly.

!The slot the boards are plugged into is defective. Try another slot until you find one that works.

!The board might be defective.

2.After the system reboots, the error message “CP-132U Series (BusNo=x, DevNo=x, Port1=COMx) interrupt number is invalid!” appears.

This indicates that the MOXA board was found, but the IRQ conflicts with another adapter. Make sure the MOXA board’s IRQ does not conflict with other adapters’ IRQ. Check the PCI BIOS IRQ settings and select an available IRQ for MOXA boards.

6-4 CP-132U Series User’s Manual