MOXA PComm Utility

Software Installation

4.Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger levels from High to Low are available, with the default value set to High (120 bytes). Check Set the change to all ports check-box to apply the just defined Rx FIFO Trigger to all ports.

5.Select a Tx FIFO Size from the Tx FIFO Level pull-down list. Tx FIFO Levels from High to Low are available, with the default value set to High (128 bytes). Check Set the change to all ports check-box to apply the just defined Tx FIFO Size to all ports.

 

CP-132UL V2/CP-132UL-I V2

CP-132UL/CP-132U-I

 

Tx FIFO

Rx FIFO

Tx

Rx FIFO

 

 

 

FIFO

 

High

128

120

64

56

Middle

64

60

32

28

Low

1

1

1

1

Unit: Bytes

6.Click OK in the Port X dialog box to confirm the port settings, and then click OK in the Property dialog box to complete the port settings.

MOXA PComm Utility

This utility, which comes with MOXA PComm Lite, provides a convenient way to diagnose Moxa board problems, and provides internal and external testing of IRQ, TxD/RxD, UART, CTS/RTS, DTR/DSR, etc. This program can verify the correct operation of both the H/W and S/W for all Moxa boards and ports.

Event Log

To check the Event Log for MOXA boards, click Start # Settings # Control Panel # Administrative Tools # Event Viewer, to enter the Event Viewer program. The latest information relevant to the Moxa driver is under the system category.

CP-132U Series User’s Manual 3-21