1. Select any two ports as redundant ports.

2. Connect the redundant ports to form the Turbo Ring

The user does not need to set the master to use Turbo Ring. Master is only needed to identify which segment acts as the backup path. The actual topology of the redundant ring, i.e., which segment will be blocked, is determined by the number of EDSs that make up the ring and where the “Ring Master” is located.

When the number of EDS units in the Turbo Ring is even.

Master

If there are 2N EDS units

(an even number) in the Turbo Ring, then the backup segment is one of the two segments connected to the (N+1)st EDS (i.e., the EDS unit directly opposite the Master).

3-18

Page 34
Image 34
Moxa Technologies EDS-508 user manual When the number of EDS units in the Turbo Ring is even