EDS-508 Series User’s Manual

Featured Functions

2.Configuring Email Settings

To configure EDS’s email setup from the Console interface or browser interface, enter your Mail Server IP/Name (IP address or name), Account Name, Account Password, Retype New Password, and the email address(es) to which warning messages will be sent.

3.Activate your settings and test email if necessary

After configuring and activating your MOXA EtherDevice Switch’s Event Types and Email Setup, you can use the Test Email function to see if your e-mail addresses and mail server address have been properly configured.

Email Alarm Events Settings

Event Types

Event Types can be divided into two basic groups: System Events and Port Events. System Events are related to the overall function of the Switch, whereas Port Events are related to the activity of a specific port.

System Event

Warning e-mail is sent when…

Switch Cold Start

Power is cut off and then reconnected.

 

 

Switch Warm Start

EDS is rebooted, such as when network parameters

 

are changed (IP address, netmask, etc.).

Power Transition (On"Off)

EDS is powered down.

Power Transition (Off"On)

EDS is powered up.

DI1 (On"Off)

Digital Input 1 is triggered by on to off transition

DI1 (Off"On)

Digital Input 1 is triggered by off to on transition

 

 

DI2 (On"Off)

Digital Input 2 is triggered by on to off transition

 

 

DI2 (Off"On)

Digital Input 2 is triggered by off to on transition

 

 

Configuration Change Activated

Any configuration item is changed.

 

 

Comm. Redundancy Topology

If any Spanning Tree Protocol switches have

Changed

changed their position (applies only to the root of the

 

tree).

 

If Master of Turbo Ring has changed or backup path

 

is activated.

Authentication Failure

An incorrect password is entered.

 

3-48