Moxa Technologies EDS-508 user manual Power, Mechanical, Environment, Regulatory Approvals

Models: EDS-508

1 92
Download 92 pages 24.48 Kb
Page 88
Image 88

EDS-508 Series User’s Manual

Specifications

Power

 

Input Voltage

12 to 48 VDC, redundant inputs

Input Current (@24V)

0.29A: (EDS-508)

 

0.43A: (EDS-508-MM-SC, EDS-508-SS-SC)

Connection

Two removable 6-pin terminal blocks

Overload Current

Present, can withstand 1.6A

Protection

 

Reverse Polarity

Present

Protection

 

Mechanical

 

Casing

IP30 protection, aluminum case

Dimensions

80.5 x 135 x 105 mm (W x H x D)

Weight

1.04 kg

Installation

DIN-Rail, Wall Mounting (optional kit)

Casing

IP30 protection, aluminum case

Environment

 

Operating Temperature

0 to 60°C (32 to 140°F)

 

-40 to 75°C (for "-T" models)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative

5% to 95% (non-condensing)

Humidity

 

Regulatory Approvals

 

Safety

UL60950, UL 508, CSA C22.2 No. 60950,

 

EN60950(E212360)

Hazardous Location

UL/cUL Class I, Division 2, Groups A, B, C and D (E238559).

 

ATEX Class I, Zone 2, EEx nC IIC (03CA24537)

EMI

FCC Part 15, CISPR (EN55022) class A

EMS

EN61000-4-2 (ESD), Level 3

 

EN61000-4-3 (RS), Level 3

 

EN61000-4-4 (EFT), Level 3

 

EN61000-4-5 (Surge), Level 3

 

EN61000-4-6 (CS), Level 3

Shock

IEC60068-2-27

Freefall

IEC60068-2-32

Vibration

IEC60068-2-6

MTBF

260,000 hours

WARRANTY

5 years