EDS-508 Series User’s Manual

Featured Functions

 

 

 

 

 

Port Event

Warning e-mail is sent when…

 

 

Link-on

The port is connected to another device.

 

 

Link-off

The port is disconnected (e.g., the cable is pulled

 

 

out, or the opposing device shuts down).

 

 

 

 

 

Traffic-Overload

The port’s traffic surpasses the Traffic-Threshold for

 

 

that port (provided this item is Enabled).

 

 

 

 

 

Traffic-Threshold (%)

Enter a nonzero number if the port’s

 

 

Traffic-Overload item is Enabled.

 

 

 

 

 

 

A Traffic-Overload warning is sent every

 

 

Traffic-Duration (sec.)

Traffic-Durationseconds if the average

 

 

Traffic-Threshold is surpassed during that time

 

 

 

 

 

 

period.

 

 

 

 

 

NOTE

The Traffic-Overload,Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items

 

are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero

 

Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

 

 

 

 

NOTE

Warning e-mail messages will have sender given in the form:

 

Moxa_EtherDevice_Switch_0001@Switch_Location

 

where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is EDS’s serial number, and

 

Switch_Location is the default Server Location.

 

Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.