EDS-508 Series User’s Manual

Featured Functions

2.Activate your settings

After configuring and activating your MOXA EtherDevice Switch’s Relay Event Types.

Relay Alarm Events Settings

Event Types

Event Types can be divided into two basic groups: System Events and Port Events. System Events are related to the overall function of the Switch, whereas Port Events are related to the activity of a specific port.

MOXA EtherDevice Switch supports two relay outputs. You can configure which relay output is related to which events. This helps administrators identify the importance of the different events.

System Event

Warning Relay output is triggered when…

Power Transition (On"Off)

EDS is powered up.

Power Transition (Off"On)

EDS is powered down.

DI1 (On"Off)

Digital Input 1 is triggered by on to off transition

DI1 (Off"On)

Digital Input 1 is triggered by off to on transition

DI2 (On"Off)

Digital Input 2 is triggered by on to off transition

 

 

DI2 (Off"On)

Digital Input 2 is triggered by off to on transition

 

 

Port Event

Warning e-mail is sent when…

 

 

Link-on

The port is connected to another device.

 

 

Link-off

The port is disconnected (e.g., the cable is pulled

out, or the opposing device shuts down).

 

Traffic-Overload

The port’s traffic surpasses the Traffic-Threshold for

that port (provided this item is Enabled).

 

Traffic-Threshold (%)

Enter a nonzero number if the port’s

Traffic-Overload item is Enabled.

 

 

A Traffic-Overload warning is sent every

Traffic-Duration (sec.)

Traffic-Durationseconds if the average

Traffic-Threshold is surpassed during that time

 

 

period.

 

 

 

3-51

Page 67
Image 67
Moxa Technologies EDS-508 user manual Relay Alarm Events Settings, Activate your settings