MRV Communications LX-4000 Series manual Appendix a Technical Specifications

Models: LX-4000 Series

1 65
Download 65 pages 52.56 Kb
Page 47
Image 47

 

 

Appendix A - Technical Specifications

 

 

 

 

 

 

 

 

 

Power Requirements

LX-4008 AC - 11W, (38BTU/hr) 0.09A at 120V (typ), 11W 0.05A

 

 

 

at 220V (typ)

 

 

 

LX-4008 DC - -48VDC Nominal, -20VDC to -72VDC Operating

 

 

 

Range, 1A @ -48VDC, Dual Feed, 165 BTU/hr

 

 

 

LX-4016 AC - 14W, (47.8 BTU/hr) 0.11A at 120V (typ), 14W

 

 

 

0.06A at 220V (typ)

 

 

 

LX-4016 DC - -48VDC Nominal, -20VDC to -72VDC Operating

 

 

 

Range, 1.2A @ -20VDC, Dual Feed, 165 BTU/hr

 

 

 

LX-4032AC- 23W, (79 BTU/hr) 0.19A @ 120V (typ), 0.105A @

 

 

 

220V

 

 

 

LX-4032DC- -48VDC Nominal, -20VDC to -72VDC Operating

 

 

 

Range, 0.6A @ 48VDC, Dual Feed, (99 BTU/hr)

 

 

 

LX-4048AC- 41W, (140 BTU/hr) 0.24A @ 120V (typ), 0.13A @

 

 

 

220V

 

 

 

 

 

 

Minimum Software

LX-4008 requires V2.0.0 or greater, LX-4016 requires V2.0.1 or

 

 

Requirements

greater, LX-4032 requires V2.2.0 or greater, LX-4048 requires

 

 

 

V3.0.0 or greater.

 

 

 

 

 

 

Ethernet Interface

10BASE-T/100Base-TX on single RJ-45, Auto-negotiation, Stan-

 

 

 

dard CSMA/CD or Full-Duplex operation.

 

 

 

 

 

 

Control Output Ratings

RTS/DTR: 5.0V @ 1.6mA (Nominal), 2.5V @ 7.6mA (Absolute

 

 

 

Maximum)

 

 

 

 

 

 

Real Time Clock

32.768KHz crystal

 

 

Battery

Lithium coin cell battery CR2032 or equivalent. Power down

 

 

 

shelf-life: 1 year at 200C.

 

451-0308

MRV Communications, Inc.

www.mrv.com

47

Page 47
Image 47
MRV Communications LX-4000 Series manual Appendix a Technical Specifications