Appendix D - Cabling the LX-4000 Series

Cabling Considerations

Standard cabling items available from MRV allow you to connect to any serial device that uses male

or female DB-25 or DB-9 connectors. All you need is the appropriate cable (crossover cable for connecting to a DTE (Data Terminal Equipment) device, straight-through cable for connecting to a

DCE (Data Communication Equipment) device), and the correct modular adapter (male or female DB- 25 connector), which is essentially an RJ-45-to-DB25 adapter.

Serial Device Connectors

The signal assignments of the 8-pin jacks are shown in Figure 23.

1

2

3 4 5 6

7

8

8

7

6 5 4 3

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rj-45 Jack

Rj-45 Plug

(Female)

(Male)

Pin Signal

1CTS

2DTR

3TXD

4SGND

5SGND

6RXD

7DSR

8RTS

Figure 23 - Serial Device Connector (RJ-45) Signal Assignments

Diagnostic Port Connector (Port 0)

The pinout for the Diagnostic Port connector is the same as that of the serial connector.