11
TOP EXIT / HORIZONTAL TERMINATION
|
| (HT) > (VT) |
|
|
| Example 2: |
| |||
|
|
|
|
| FIGURE 9 |
| V1 | = VT | = 6 ft |
|
|
|
|
|
|
| H1 | = 3 ft |
| ||
|
|
|
|
|
|
| H2 | = 5 ft |
| |
|
|
|
|
|
|
| HR | = H1 | + H2 = 3 + 5 = 8 ft | |
Simple venting configuration |
|
|
| HO | = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft | |||||
|
|
| HT | = HR + HO = 8 + 2.7 = 10.7 ft | ||||||
(only one 90° elbow) |
|
|
| |||||||
|
|
| HT | + VT= 10.7 + 6 =16.7 |
| |||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Formula 1: | HT < 4.2 VT |
| |
|
|
|
|
|
|
|
|
| 4.2 VT = 4.2 x 6 = 25.2 ft | |
|
|
|
|
|
|
|
|
| 10.7 < 25.2 |
|
|
|
|
|
|
|
| Formula 2: | HT + VT < 24.75 feet | ||
|
|
|
|
|
|
|
|
| 16.7 < 24.75 |
|
|
|
|
|
|
|
| Since both formulas are met, this vent configuration is | |||
See graph to determine the required vertical rise VT for the | acceptable. |
|
| |||||||
|
|
|
| |||||||
required horizontal run HT. |
|
|
|
| Example 3: |
| ||||
REQUIRED | 150 |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
140 |
|
|
|
|
|
|
|
|
| |
VERTICAL |
|
|
|
|
|
|
|
| 90° | |
RISE IN | 130 |
|
|
|
|
|
|
|
| |
INCHES VT | 120 |
|
|
|
|
|
|
| H1 | H4 |
|
|
|
|
|
|
|
| |||
| 110 |
|
|
|
|
|
|
|
| V2 |
| 100 |
|
|
|
|
|
|
|
| H3 |
|
|
|
|
|
|
| V1 | 90° | H2 | |
| 90 |
|
|
|
|
|
| FIGURE 11 | ||
| 80 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
| 70 |
|
|
|
|
|
|
|
|
|
| 60 |
|
|
|
|
|
|
|
|
|
| 50 |
|
|
|
|
|
|
|
|
|
| 40 |
|
|
|
|
| V1 | = 4 ft |
| |
| 30 |
|
|
|
|
|
| |||
|
|
|
|
|
| V2 | = 1.5 ft |
| ||
|
|
|
|
|
|
|
| |||
| 20 |
|
|
|
|
| VT | = V1 + V2 = 4 + 1.5 = 5.5 ft | ||
| 10 |
|
|
|
|
| H1 | = 2 ft |
| |
|
| 0 | 5 | 10 | 15 | 20 | H2 | = 1 ft |
| |
|
| H3 | = 1 ft |
| ||||||
HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT |
| H4 | = 1.5 ft |
| ||||||
|
|
|
|
|
|
| HR | = H1 + H2 + H3 + H4 | = 2 + 1 + 1 + 1. 5 = 5.5 ft | |
The shaded area within the lines represents acceptable | HO | = .03(four 90° elbows - 90°) = .03(360° - 90°) = 8.1 ft | ||||||||
values for HT and VT . |
|
|
|
| HT | = HR + HO = 5.5 + 8.1 = 13.6 ft | ||||
|
|
|
| HT | + VT = 13.6 + 5.5 = 19.1 ft | |||||
|
|
|
|
|
|
| ||||
For vent configurations requiring more than one 90° elbow | Formula 1: HT < 4.2 VT |
| ||||||||
the following formulas apply: |
|
|
|
|
|
| 4.2 VT = 4.2 x 5.5 = 23.1 ft | |||
Formula 1: HT | < 4.2 VT |
|
|
|
|
| 13.6 < 23.1 |
| ||
Formula 2: HT | + VT < 24.75 feet |
|
| Formula 2: HT + VT < 24.75 feet | ||||||
|
|
| H1 |
|
|
|
|
| 19.1 < 24.75 |
|
FIGURE10 |
|
|
| H2 |
| Since both formulas are met, this vent configuration is | ||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
| acceptable. |
|
| |
| V1 |
| 90° |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|