Napoleon Fireplaces GD19P Adjustments, Pilot Injector And Orifice Replacement, Venturi Adjustment

Models: GD19N GD19P

1 36
Download 36 pages 28.06 Kb
Page 30
Image 30
ADJUSTMENTS

30

ADJUSTMENTS

PILOT INJECTOR AND ORIFICE REPLACEMENT

1. Turn off the electrical

FIGURE 64

and gas supply to the

 

fireplace.

 

2.Remove the front, glass viewing door and log set.

3.Remove the 2 securing screws. Slide the burner assembly to the right and lift out.

4.Using a deep 9/16” socket wrench, remove the main burner orifice.

A 7/8back-up wrench

 

 

must be used on the

ORIFICE

 

manifold, located below

 

LOCATION

 

the housing to ensure that

BURNER

 

the aluminum tubing does

 

ASSEMBLY

not twist or kink. Replace

 

 

the correct burner orifice

FIGURE 65

using pipe thread compound.

5. Loosen nut and replace with appropriate pilot injector

6. Reinstall the burner ensuring that the Venturi tube fits over the orifice.

NOTE: Check and adjust, if necessary, the primary air to 1/16” for propane and 1/32" for natural gas. Replace the screws.

7.Turn on the gas supply and check for gas leaks by brushing on a soap and water solution.

Do not use open flame.

8.Replace the log set. Then light the pilot and main burner to ensure that the gas lines have been purged.

9.Replace the glass viewing door and cast front. Turn on the electrical supply to the fireplace.

Purge all gas lines with the glass door removed. Assure that a continuous flow is at the burner before re-installing the door.

This must be carried out by an AUTHORIZED REPRESENTATIVE OF WOLF STEEL LTD. or a QUALIFIED GAS INSTALLER in accordance with local codes or in the absence of local codes with the requirements of the provincial / state authorities having jurisdiction and in accordance with the requirements of the CAN1-B149 Installation Code in Canada and the ANSI Z223.1 National Fuel Gas Code in the United States.

VENTURI ADJUSTMENT

Remove the 2 screws securing the burner. Natural gas models have air shutters set to 0.031" open (1/32"). Propane models have air shutters set to 0.063" open (1/16").

After making adjustments replace the burner ensuring that the venturi tube fits over the orifice and replace the screws.

Closing the air shutter will cause a more yellow flame, but can lead to

FIGURE 66 carboning. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

Air shutter adjustment must only be done by a qualified gas installer!

For fuel conversion refer to the instructions included with your conversion kit.

FLAME ADJUSTMENT

Turn counterclockwise

I

O

Turn clockwise to

to decrease flame

P

L

T

increase flame height

height

F

 

 

O

 

O

 

 

N

 

F

 

 

 

 

 

 

 

FIGURE 67

FLAME ADJUSTMENT Manual Shut-off Valve

KNOB

 

 

 

Shown in “OFF”

 

 

 

 

position.

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustrations provided.

FIGURE 68

W415-0612 / C / 01.25.08

Page 30
Image 30
Napoleon Fireplaces GD19P Adjustments, Pilot Injector And Orifice Replacement, Venturi Adjustment, Flame Adjustment, Knob