Napoleon Fireplaces GD19N, GD19P manual Rear Exit / Horizontal Termination

Models: GD19N GD19P

1 36
Download 36 pages 28.06 Kb
Page 13
Image 13
Manual background

13

REAR EXIT / HORIZONTAL TERMINATION

(HT) > (VT)

Example 5:

 

90°

Simple venting configuration

 

 

 

90°

H4

(only two 90° elbows)

 

 

 

 

V2

 

H2

 

90°

 

 

 

H3

 

FIGURE 14

V1

45°

 

 

 

H1

FIGURE 15

90°

 

See graph to determine the required vertical rise VT for the required horizontal run HT

 

150

 

 

V1

=4 ft

147

 

 

V2

=1.5 ft

 

 

 

REQUIRED

 

 

 

VT

= V1 + V2 = 4 + 1.5 = 5.5 ft

VERTICAL

 

 

 

H1

=2 ft

RISE IN

 

 

 

H2

=1 ft

INCHES VT

 

 

 

H3

=1 ft

 

 

 

H4

=1.5 ft

 

 

 

 

 

100

 

 

HR

= H1

+ H2 + H3 + H4 = 2 + 1 + 1 + 1.5 = 5.5 ft

 

 

 

 

HO

= .03(four 90° elbows + one 45° elbow - 90°)

 

 

 

 

 

= .03(90 + 90 + 90 + 90 + 45 - 90) = 9.45 ft

 

 

 

 

HT

=HR + HO = 5.5 + 9.45 = 14.95 ft

66

 

 

 

HT + VT

= 14.95 + 5.5 = 20.45 ft

 

 

 

Formula 1:

HT < 3.5VT

 

 

 

 

 

50

 

 

 

 

3.5VT = 3.5 x 5.5 = 19.25 ft

 

 

 

 

 

 

14.95 < 19.25

 

 

 

 

Formula 2:

HT + VT < 24.75 feet

 

 

 

 

 

 

20.45 < 24.75

 

 

 

 

Since both formulas are met, this vent configuration is

12

10

 

 

acceptable.

 

 

 

 

 

 

 

 

0

5

 

15

 

 

 

 

3.4

12.5

19.

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

 

 

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than two 90° elbows the following formulas apply:

Formula 1: HT < 3.5VT

Formula 2: HT + VT < 24.75 feet

W415-0612 / C / 01.25.08

Page 13
Image 13
Napoleon Fireplaces GD19N, GD19P manual Rear Exit / Horizontal Termination