Napoleon Fireplaces GD19P, GD19N manual Top Or Rear Exit Vertical Termination, Ht Vt

Models: GD19N GD19P

1 36
Download 36 pages 28.06 Kb
Page 14
Image 14
TOP OR REAR EXIT VERTICAL TERMINATION

14

TOP OR REAR EXIT VERTICAL TERMINATION

(HT) < (VT)

Example 6:

 

 

 

FIGURE 17

90°

V3

 

FIGURE 16

90°

H2

 

V2

 

V1

H1

90°

 

 

 

 

90°

See graph to determine the required vertical rise VT for the

V1

=3 ft

V2

=6 ft

required horizontal run HT.

 

 

 

 

 

 

 

 

V3

=8 ft

 

 

 

 

 

 

 

VT

= V1 + V2 + V3 = 3 + 6 + 8 = 17 ft

 

 

 

 

 

 

 

H

=2 ft

 

35

 

 

 

 

 

H21

=2.5 ft

 

30

 

 

 

 

 

HR

= H1

+ H2 = 2 + 2.5 = 4.5 ft

REQUIRED

 

 

 

 

 

HO

= .03(four 90° elbows - 90°)

 

 

 

 

 

 

HT

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

VERTICAL

 

 

 

 

 

 

=HR + HO = 4.5 + 8.1 = 12.6 ft

RISE IN

20

 

 

 

 

 

HT + VT

= 12.6 + 17 = 29.6 ft

FEET VT

 

 

 

 

 

Formula 1:

HT < VT

17.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6 < 17

 

 

 

 

 

 

 

Formula 2:

HT + VT < 35 feet

 

10

 

 

 

 

 

 

 

29.6 < 35

 

 

 

 

 

 

 

Since both formulas are met, this vent configuration is

3

 

 

 

 

 

 

acceptable.

 

 

0

5

10

15

17.5

20

 

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 35 feet

W415-0612 / C / 01.25.08

Page 14
Image 14
Napoleon Fireplaces GD19P, GD19N manual Top Or Rear Exit Vertical Termination, Ht Vt