Napoleon Fireplaces GD19P Using Flexible Vent Components, Horizontal Air Terminal Installation

Models: GD19N GD19P

1 36
Download 36 pages 28.06 Kb
Page 18
Image 18
USING FLEXIBLE VENT COMPONENTS
FIGURE 25

18

USING FLEXIBLE VENT COMPONENTS

ELBOW

SPACERS

!WARNING

Do not allow the 4" flexible vent pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1 1/4” air gap between the 4" and 7" flexible vent pipes all around is required for safe operation. A spacer is required at the start, middle and end of each elbow to ensure this gap is maintained. Spacers are attached to the 4" flexible vent pipe at predetermined intervals to maintain a 1-1/4” air gap to the 7" flexible vent pipe. These spacers

must not be removed.

Use only approved flexible vent pipe kits marked:

FIGURES 22a&b

“Wolf Steel Approved Venting” as identified by the stamp only on the 7” flexible vent pipe.

Six inches (6") is the minimum bend radius allowed for the seven inch (7") diameter flexible vent pipe.

For optimum performance it is recommended that all horizontal runs have a minimum 1" rise per foot using flexible vent components.

For safe and proper operation of the fireplace, follow the venting instructions exactly.

All 4" flexible vent pipe and 7" flexible vent pipe joints may be sealed using high temperature sealant W573-0002 (not supplied) or the high temperature sealant W573-0002 Mill Pac (not supplied). However, the high temperature sealant W573-0007 Mill Pac (not supplied) must be used on the joint connecting the 4" flexible vent and the exhaust flue collar.

HORIZONTAL AIR TERMINAL INSTALLATION

For safe and proper operation of the fireplace, follow the venting instructions exactly.

1.Stretch the 4" flexible vent pipe to the required length taking into account the additional length needed for the finished wall surface. Slip the vent pipe a minimum of 2" over the inner sleeve of the air terminal and secure with 3 #8 screws. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied).

NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off.

CAUT

 

ATTENTI

ION-

 

HOT

 

ON-

 

CHAUD

CAULKING

4" FLEXIBLE VENT PIPE

7" FLEXIBLE

2. Using the 7" flexible vent pipe, slide over the outer combustion air

 

 

2" OVERLAP

VENT PIPE

 

 

 

sleeve of the air terminal and secure with 3 #8 screws. Seal using high

 

 

 

 

 

temperature sealant W573-0002 (not supplied).

FIGURE 23

 

HIGH TEMPERATURE

3. Insert the vent pipes through the firestop maintaining the required

#10x2"

 

SEALANT

 

SCREWS

 

 

clearance to combustibles. Holding the air terminal (lettering in an upright,

HIGH

 

#8 X 1/2”

 

 

readable position), secure to the exterior wall and make weather tight by

 

 

 

 

SELF DRILLING

sealing with caulking (not supplied).

TEMPERATURE

SCREWS AND

FIGURE 24

4. If more vent pipe needs to be used to reach the fireplace, couple them

SEALANT

 

WASHERS

 

 

 

 

 

together as illustrated. The vent system must be supported approximately

 

 

4” COUPLER

 

7” COUPLER

every 3 feet for both vertical and horizontal runs. Use noncombustible

 

 

 

 

 

strapping to maintain the minimum 1" clearance to combustibles.

 

 

 

7” FLEXIBLE

 

 

 

 

The air terminal mounting plate may be recessed into the exterior wall

7” FLEXIBLE

 

 

VENT PIPE

 

4”

 

 

or siding by 1½", the depth of the return flange.

VENT PIPE

 

FLEXIBLE

 

 

VENT PIPE

VERTICAL AIR TERMINAL INSTALLATION

1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having

jurisdiction or the optional roof support. Figure 25.

2.Stretch the 4" flexible vent pipe to the required length. Slip the 4" flexible vent pipe a minimum of 2” over the inner sleeve of the air terminal connector and secure with 3 #8 screws. Seal using a heavy bead of high temperature sealant W573-0007 (not supplied). Figure 26.

NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off.

3. Repeat using the 7" flexible vent pipe, using a heavy bead of high temperature

ROOF SUPPORT

sealant W573-0002 (not supplied). Figure 26.

 

W415-0612 / C / 01.25.08

Page 18
Image 18
Napoleon Fireplaces GD19P, GD19N manual Using Flexible Vent Components, Horizontal Air Terminal Installation