Chapter5 MachineVision
IMAQVision for LabWindows/CVI User Manual 5-14 ni.com
Figure5-7. Symmetry
Feature detailA templatewith relatively coarse features is less sensitive to variations in
sizeand rotation than a model with fine features. However, the model must
contain enough detail to identify it.
Figure5-8. FeatureDetail
Positional informationA templatewith strong edges in both the x and y directions is easier to
locate.
Figure5-9. PositionalInformation
Rotationally
Symmetric
Rotationally
Asymmetric
Good
FeatureDetail
Ambiguous
FeatureDetail
GoodPositional
Informationin x and y
InsufficientPositional