5-32 Problem Solving
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message Description Action
0B45 System
Configuration Data
Write Error
Write error on the data configuring
the system.
Start the SETUP utility, execute [Advanced]
[Advanced] [Reset Configuration
Data].
If the error persists, contact your service
representative to replace the riser card or
system I/O board.
0B46 ESMINT not
configured
Interrupt request for PCI board
and ESM are incorrect.
Start the SETUP utility, and specify the
correct value for [System Hardware]
[ESM IRQ] and [Advanced] [PCI Device]
[PCI IRQ], then restart the server.
If the error persists, contact your service
representative to replace the I/O riser board
or system I/O board.
0B50 CPU #1 with error
taken off line.
Because an error was detected in
CPU #1, it was degraded.
0B51 CPU #2 with error
taken off line.
Because an error was detected in
CPU #2, it was degraded.
0B52 CPU #3 with error
taken off line.
Because an error was detected in
CPU #3, it was degraded.
0B53 CPU #4 with error
taken off line.
Because an error was detected in
CPU #4, it was degraded.
0B54 CPU #5 with error
taken off line.
Because an error was detected in
CPU #5, it was degraded.
0B55 CPU #6 with error
taken off line.
Because an error was detected in
CPU #6, it was degraded.
0B56 CPU #7 with error
taken off line.
Because an error was detected in
CPU #7, it was degraded.
0B57 CPU #8 with error
taken off line.
Because an error was detected in
CPU #8, it was degraded.
The displayed CPU is degraded. Contact
your service representative to replace the
failed CPU.
0B5F Forced to use CPU
with error
CPU error is detected. The system is started forcibly because
errors are detected on all CPUs. Contact
your service representative to replace the
CPU.
0B60 DIMM group #1 has
been disabled
A memory error was detected in
memory DIMM group #1. Memory
DIMM group #1 is degraded.
0B61 DIMM group #2 has
been disabled
A memory error was detected in
memory DIMM group #2. Memory
DIMM group #2 is degraded.
0B62 DIMM group #3 has
been disabled
A memory error was detected in
memory DIMM group #3. Memory
DIMM group #3 is degraded.
0B63 DIMM group #4 has
been disabled
A memory error was detected in
memory DIMM group #4. Memory
DIMM group #4 is degraded.
Contact your service representative to