Configuring Your System 3-15

System Hardware Menu
Feature
Choices or
Display Only Description Your Setting
Thermal Sensor Refer to Thermal Sensor
Submenu.
Wake On Events Refer to Wake On Events
Submenu.
AC Link Power On
Last State
Stay Off
Determines the mode of AC
Link. This determines the state
of the server when AC power
is reapplied (see Table below).
Note: When "Wake On LAN" is
enabled, Stay Off is the only
choice for selection.
ESM IRQ Disabled
IRQ5
IRQ10
IRQ11
Determines routing of the ESM
interrupt.
Error Log
Initialization
Press Enter Request to initialize the Error
Log now.
If Clear OK, then display
"System Event Log Cleared!"
If Clear NG, then display
"System Event Log Not
Cleared!"
Console
Redirection
Additional setup menu to
configure console.
The Boot-Time diagnostic
screen is enabled if redirection
is enabled.

Server Power State Versus AC Link Settings

Setting
State Before Power Off
Stay Off Last State Power On
In Service Off On On
Out of Service (DC Power Off) Off Off On
Forced Shutdown* Off Off On