Reference Manual for the ProSafe Network Management System NMS100

4.Add an Event Filter for the pollDeviceDown event

a.Locate the ProSafe NMS Selection Tool at the left side of the console. If it is not there, use the View/ Selection Tool to show it.

b.Select the Event tab on the Selection Tool.

c.Open the Snmpc-Status-Polling subtree, which contains all polling related event actions.

d.Open the pollDeviceDown subtree, which contains all event filters for the Device Down event.

e.Right-click on the Default event filter and use the Insert Event Filter menu to add a new event filter.

The Add Event Filter dialog is displayed.

f.Enter an Event Name for the new event filter at the General tab. For example, set the name to Primary Router Down.

5.Select the devices to match the Event Filter

a.Select the Match tab of the displayed Add Event Filter dialog.

b.Click the Add button.

c.Use the tree control to select one or more device names and click OK.

d.The matching device names are displayed in the Sources list box.

4-8

Polling and Emailing

September 2004 202-10058-01

Page 44
Image 44
NETGEAR NMS100 manual Add an Event Filter for the pollDeviceDown event