New Buck Corporation 20 Room Heater manual DOOR GASKET REPLACEMENT Cold Heater

Models: 20 Room Heater

1 62
Download 62 pages 31.99 Kb
Page 35
Image 35
DOOR GASKET REPLACEMENT (Cold Heater)

4. Using penetrating oil, generously lubricate the four (4) bolt threads holding the catalyst housing in place. Allow to penetrate.

5. Using a 9/16” wrench or 9/16” socket, loosen the four (4) bolts and remove the catalyst housing (drop down) and place in a suitable work area.

6. Using needle nose pliers, grasp the front edge of the stainless steel “can” which houses a catalytic element and pull upward.

7. Using a small putty knife or scraper, remove any gasket that may have adhered to the catalyst housing.

8. Now, obtain the new catalysts and wrap the stainless steel “can” with interam gasket and tape ends together using scotch tape or masking tape.

9. Insert the new catalysts into the catalytic housing and push down until they are seated on the top of the stainless steel wire mesh supports.

10. Reinstall the catalyst housing into the stove and secure in place with the bolts.

11. The stove is now ready for use.

2” X 2” X 7” STANDARD 25 CELL

Manual backgroundCORNING LONG LIFE CATALYSTS

 

1/16” THICK INTERAM GASKET AND

 

STAINLESS STEEL CAN (2 EA.)

 

1/16” THICK INTERAM GASKET

 

(LAP ENDS 1/4” AND TAPE)

BOLT HOLES

APPLY 1/16”X 1/2” FIBERGLASS

 

GASKET COMPLETELY AROUND

 

SEALING LIP.

 

CATALYST HOUSING

 

(STEEL OR CAST IRON)

 

FRONT

DOOR GASKET REPLACEMENT (Cold Heater)

To replace deteriorated gaskets, the following steps must be taken to ensure proper installation of gaskets.

1.Obtain the proper gaskets and silicone glue from your local dealer.

2.Using pliers, remove any worn and deteriorated gaskets.

3.Using a scraper, wire brush, and sandpaper or steel wool, clean glue and gasket residue from the door frame.

4.Measure and cut gaskets to length. Care should be taken not to stretch the gaskets. What you want is a full and loose gasket weave after attachment to the framing.

5.Obtain the silicone glue and run a 3/16” bead inside the door frame.

6.Obtain the gasket (s) and place in the gasket channel areas. Use a technique which assures that the gasket is applied in a loose like manner. DO NOT STRETCH GASKETS.

7.After gasket (s) are applied to the glue, use your finger and go over all the gasket gently pressing the gasket to the channel. Use the same pressure against the gasket so that the final result is an evenly applied gasket.

8.Leave door open and allow at least one hour for the glue to dry.

ROPE GASKET

Manual backgroundManual backgroundManual background SILICONE

Page 35
Image 35
New Buck Corporation 20 Room Heater manual DOOR GASKET REPLACEMENT Cold Heater

FAQ

How do I replace the catalyst housing of my New Buck Corporation model 20 Room Heater?

Follow our guide to learn how to replace the catalyst housing and maintain the functionality of your heater.

Where can I obtain the proper gaskets and silicone glue for door gasket replacement?

You can get the necessary gaskets and silicone glue from your local dealer.

How long should I leave the door open after applying the silicone glue for the rope gasket?

Leave the door open for at least one hour to allow the glue to dry properly.