New Buck Corporation 20 Room Heater manual Required Fireplace Dimensions, Installation Preparation

Models: 20 Room Heater

1 62
Download 62 pages 31.99 Kb
Page 9
Image 9

REQUIRED FIREPLACE DIMENSIONS

Minimum and/or maximum fireplace dimensions:

 

 

 

 

Height

 

 

Width

Depth

 

Min.

Max.

Min.

Max.

Min.

Model 20

22”

31”

26”

41”

16”

POSSIBLE TOOLS NEEDED FOR INSTALLATION

If you decide to install your own stove, there are several hand tools you may need to do the job. If you do not already have them, they are readily available at most hardware stores.

Caulking gun

Large adjustable wrench (may not be needed) Drop cloths or newspapers

Vacuum cleaner or whisk broom Flashlight

1 tube of RTV silicone, Code 103 or 106, or high temperature rubber cement rated between 450o F- 600o F 7/32” drill bit and drill

Socket/Rachet Set

INSTALLATION PREPARATION

Fireplace:

1.Locate furniture and other materials away from the front of the fireplace to allow free access to the fireplace.

2.Cover the hearth and adjacent floor areas with the drop cloths to protect from soiling or marring the surface.

3.Remove the existing fireplace damper plate.

4.Thoroughly clean the fireplace of ashes and soot.

5.Check the chimney and smoke chamber for excessive buildup of creosote or soot. Also, check for obstructions, such as bird’s nests. If the chimney is excessively dirty, clean it, or have someone clean it professionally BEFORE installing or using the room heater.

6.If the fireplace has an ash dump or outside air provision, these must be sealed off with metal or tightly packed non-combustible insulation to prevent cold air from entering the fireplace chamber.

Heater:

1.Inspect the unit for any obvious physical damage.

2.Plug the power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to “High” position to ensure motor operates properly.

3.Check the primary air draft control to ensure that it operates freely.

4.Check the operations of the damper control to ensure it will open and close properly.

5.If unit is a fireplace insert remove rear side panels and place screws back in the holes before setting the unit in the fireplace opening.

Page 9
Image 9
New Buck Corporation 20 Room Heater Required Fireplace Dimensions, Possible Tools Needed For Installation, Height, Width

FAQ

What are the minimum and maximum fireplace dimensions for the Model 20 Room Heater?

The minimum height is 22 inches, and the maximum is 31 inches. The minimum width is 26 inches, and the maximum is 41 inches. The minimum depth is 16 inches.

What tools are needed for installing the Model 20 Room Heater?

Some of the possible tools needed for installation include a caulking gun, large adjustable wrench, drop cloths, vacuum cleaner, flashlight, RTV silicone or high temperature rubber cement, drill bit and drill, and socket/ratchet set.

How should I prepare the fireplace for installation?

To prepare the fireplace, you should move furniture and materials away from the front of the fireplace, cover the hearth and adjacent floor areas with drop cloths, remove the existing fireplace damper plate, thoroughly clean the fireplace, and seal off any ash dump or outside air provision.