MASONRY INSERT INSTALLATION

SECTION II

MASONRY INSERT INSTALLATION

INSTALLATION PRECAUTIONS

Extensive field and laboratory testing has shown that catalytic stoves perform best as fireplace inserts when:

1.A direct connect kit is used to connect the stove exhaust outlet directly to the masonry flue of the fireplace when flue liner size is approximately the same size as the heater flue gas exit. A rain cap is also recommended to keep flue dry thus allowing a hotter draft.

NFPA 211 CODE: The National Fire Protection Association code requires all fireplace insert heaters to be positively connected from the heater to the flue liner (subject to State and Local codes in your area).

2.An equivalent sized flue liner is installed when the flue liner size is larger than the heater flue gas exit. Connection must be from stove exhaust outlet extending the full height of the chimney and must include a rain cap.

3.Location of chimney is interior (not on an outside wall).

Satisfactory results have been reported with installations other than as listed above. However, as all chimneys draw differently, problems with performance may be encountered if steps are not taken to keep the chimney hot. A draft between .03 and .06 inches of water is recommended for proper catalytic operation.

Use the following to complete the installation of the unit as an insert:

Kit #FP20

INSTALLATION (Fireplace Insert)

FIGURE 1

FIREPLACE INSERT

Page 7
Image 7
New Buck Corporation 20 Room Heater manual Masonry Insert Installation, Installation Precautions, Fireplace Insert, Section

FAQ

What is the best way to connect the stove exhaust outlet to the masonry flue?

The best way to connect the stove exhaust outlet to the masonry flue is by using a direct connect kit and ensuring the flue liner size is approximately the same size as the heater flue gas exit, as well as installing a rain cap to keep the flue dry.

What code requirements are there for fireplace insert heaters?

The National Fire Protection Association code requires all fireplace insert heaters to be positively connected from the heater to the flue liner, subject to State and Local codes in your area.

What is the recommended chimney location for installing the heater as an insert?

The recommended chimney location for installing the heater as an insert is interior and not on an outside wall, as satisfactory results have been reported with such installations.