F. Vertical wall exit using (6" DVL Close Clearance pipe with elbow and any listed 2100° UL 103 HT. TYPE Chimney, and

Listed 2100° UL HT T-Box assembly).

With optional close clearance shield and pipe shield. Model 21 minimum clearance to combustibles.

BACK WALL

Figure 17.

SIDE WALL

EE

PROTECTOR

 

 

Manual backgroundManual backgroundAManual background

B

H D FF

B

G

G

CC Manual backgroundManual backgroundC

A B C D E F G

MODEL 21

19” 7"

7"

8.5" 8"

3"

16"

NOTE: All clearances are to combustibles with close clearance shields and pipe shield, DVL Close Clearance pipe with elbow, and minimum floor protector.

CEILING

DVL CLOSE

CLEARANCE

PIPE

Figure 18.

optional pipe shield.

NOTE:

See Page 33 for

installation of

optional close

clearance shields

and pipe shield

optional close clearance shield

IN

SIDE WALL

LISTED 2100° UL 103 HT TYP.

CHIMNEY REEFER TO

MANUFACTURER’S INSTALLATION INSTRUCTION

LISTED 2100° UL 103 HT

TYP. CHIMNEY T-BOX

ASSEMBLY REEFER TO

MANUFACTURER’S

INSTALLATION

INSTRUCTION

WALL

PASS-THROUGH

CONNECTOR

25

Page 27
Image 27
New Buck Corporation installation instructions Listed 2100 UL HT T-Boxassembly