Installing the EtherSpeedII Switch Modules

2.Wait 45 seconds.

Waiting allows the system software to process the requests to disable the ports.

Caution: If you remove a module without waiting 45 seconds after disabling the ports, you must power cycle the Centillion 50/100 chassis. When you turn off the power on the chassis, you must wait 15 to 20 seconds before turning the power back on. The switch modules begin switching an additional 15 to 20 seconds after power is resumed.

3.Using the medium flat-tip screwdriver, loosen the two captive retaining screws on the module until they pop free of the chassis.

4.Rotate the left and right inserter/extractor levers away from the center of the module to their protruding positions (Figure 3-8).

The module is disengaged from the backplane.

6470

Figure 3-8. Disengaging the Module

207344-B

3-9