Nortel Networks 207344-B manual From the Map window in SpeedView, choose Statistics

Models: 207344-B

1 74
Download 74 pages 15.93 Kb
Page 54
Image 54

Using the Centillion EtherSpeedII Switch Modules

3.Verify that the port is transmitting and receiving data frames.

a.Check the green RJ-45 LED, which indicates a data exchange.

Refer to Appendix C, “LED Displays on the EtherSpeedII Switch Modules,” for additional information.

b.From the Map window in SpeedView, choose Statistics.

When the statistics information is displayed at the management station, verify that the octet counts for transmit and receive are incrementing. Also verify that the frame counts for transmit and receive unicast traffic and for multicast traffic are incrementing.

c.From a configuration terminal connected to the serial port on the switch, access the CLI.

Use the show port command and specify the module number and port number for the suspected port. Verify that the following counters are incrementing:

InOctet

OutOctet

InUcastPkt

OutUcastPkt

MulticastTransmittedOk

MulticastReceivedOk

BroadcastTransmittedOk

BroadcastReceivedOk

4.If the port still fails, try inserting it into another switch network or shared segment.

If the port functions correctly, check the status of the first switch network or shared segment.

If the port fails to function, contact the nearest Nortel Networks Technical Solutions Center. Be ready to give the service representative the information listed on page 4-1.