Installing the server and connecting the peripheral devices

WARNING

Risk of personal injury and risk of hardware failure

You must connect the power outlets that are used by the CallPilot server and its peripheral devices to the same single-point ground reference as the one used by the switching system connected to the CallPilot server.

If this requirement is not met, power transients can cause personal injury, hardware failure, or both. For more information on single-point grounding requirements, refer to the Installation and Configuration Task List (555-7101-210).

To connect the server to power

1Plug the server’s AC power cord into the server’s rear panel.

2Plug the other end into a wall receptacle or power bar.

To start the server

1Press the server power switch to start the server.

2Observe the Power-On Self Test (POST) and initialization messages on the monitor.

3Let the mini-setup sequence run until you are prompted to log in to the operating system.

Note: The system may perform multiple reboots. This is normal.

4Ensure that the operating system logon window appears on the monitor.

Note: If the logon window does not appear, refer to the CallPilot Maintenance and Diagnostics guide for your server for troubleshooting instructions.

5Proceed with the CallPilot server and switch configuration guide for your switch to connect and configure the server and switch.