Novatel OM-20000122 user manual Using the WinLoad Utility, Open a File to Download

Models: OM-20000122

1 57
Download 57 pages 63.2 Kb
Page 44
Image 44

Chapter 5

NovAtel Firmware and Software

 

 

5.3.2Using the WinLoad Utility

If opening WinLoad for the first time, ensure the file and communications settings are correct.

Open a File to Download

Select File Open. Navigate to the file to open (Figure 12, WinLoad’s Open Window).

Figure 12: WinLoad’s Open Window

When a file is selected, the filename appears in the main WinLoad display area and in the title bar (Figure 13, Open File in WinLoad).

Figure 13: Open File in WinLoad

Communications Settings

To set the communications port and baud rate, select Settings COM Settings. Choose the computer port to use from the Com Port drop down list and the baud rate from the Download Baudrate drop down list. Set the baud rate as high as possible (the default of 115200 and is preferred).

Figure 14: COM Port Setup

Downloading Firmware

1.Select the file to download according to Open a File to Download on page 44.

2.Ensure the file path and name are displayed in main display area (see Figure 13, Open File in WinLoad on page 44).

3.Click Write Flash to download the firmware.

4.When Searching for card appears in the main display, power cycle the receiver.

44

SPAN-CPT User Manual Rev 8

Page 44
Image 44
Novatel OM-20000122 user manual Using the WinLoad Utility, Open a File to Download