Oki ML520, ML521 manual Maintenance & Disassembly Pressure Spring

Models: ML521 ML520

1 269
Download 269 pages 15.77 Kb
Page 130
Image 130

Page: 93

Service Guide ML520/521

Chapter 3 Maintenance & Disassembly

3.2.24 Pressure Spring

1.Perform these procedures: 3.2.01, 3.2.06, 3.2.07, 3.2.16, 3.2.17, 3.2.19, 3.2.20, 3.2.22, and 3.2.23.

2.Turn the front release gear arm (1) until it is disengaged.

3.Remove the release cam (2). This is the medium size, thick cam.

4.Work the end of the pressure spring (3) free and remove the spring.

5.Remove the front release gear arm. This arm is long, with a serrated edge.

6.Remove the switch lever (4). This is the small lever.

NOTE:

Installation

Install the release cam first.

Then, install one end of the pressure spring into the release cam.

Slide the cam and spring away from the base frame until the opposite end of the spring can be installed into the frame.

Make sure that the front release gear arm is engaged as shown (A).

Lubrication

When lubricating, refer to Section 3.5 of this Service Handbook.

Page 130
Image 130
Oki ML520, ML521 manual Maintenance & Disassembly Pressure Spring