Page: 86

Service Guide ML520/521

Chapter 3 Maintenance & Disassembly

3.2.17 Right Ground Plate

1.Perform these procedures: 3.2.01, and 3.2.06.

2.Pull the top tabs (1) of the right ground plate (2) out to free the plate from the claws of the base frame. You may have to use a screwdriver to work the plate tabs free.

3.Lift the plate and remove it.

NOTE:

Installation The plate must be securely seated under the claws.

P/N 51010201 Plate: Right Ground RSPL Both B.2.05

Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)