Page: 37

Service Guide ML520/521

Chapter 2 Principles of Operation

2.1.07 Alarm Circuit

Driver Circuit Alarm Processing

The printhead driver output and the head gap magnet output drive signals are monitored at R29 and C8. The POWER OFF-P signal is output by the comparator (Location 02C: IC2901) when driven for more than the specified time. This signal becomes the ALM signal. The ALM signal is sent to the power supply board and causes the DC voltages to be turned off.

Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)

Page 54
Image 54
Oki ML521 manual Service Guide ML520/521