OME-A-822PGH GAIN CONTROL CODE TABLE

BI/UN

Settling Time

GAIN

Input Range

GAIN3

GAIN2

GAIN1

GAIN0

BI

23 us

1

+/- 5V

0

0

0

0

BI

28 us

10

+/- 0.5V

0

0

0

1

BI

140 us

100

+/- 0.05V

0

0

1

0

BI

1300 us

1000

+/- 0.005V

0

0

1

1

UNI

23 us

1

0 to 10V

0

1

0

0

UNI

28 us

10

0 to 1V

0

1

0

1

UNI

140 us

100

0 to 0.1V

0

1

1

0

UNI

1300 us

1000

0 to 0.01V

0

1

1

1

BI

23 us

0.5

+/- 10V

1

0

0

0

BI

28 us

5

+/- 1V

1

0

0

1

BI

140 us

50

+/- 0.1V

1

0

1

0

BI

1300 us

500

+/- 0.01V

1

0

1

1

BI=Bipolar, UNI=Unipolar, X=don‘t care, N/A=not available

2.4.7A/D Multiplex Control Register

(WRITE)

Base+A : A/D Multilexer Control Register Format

 

 

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

X

X

X

X

D3

D2

D1

D0

A/D input channel selection data = 4 bits : D3..D0, D3=MSB, D0=LSB, X=don‘t care

Single-ended mode : D3..D0

Differential mode : D2..D0, D3=don’t care

The OME-A-822PGL/PGH provides 16 single-ended or 8 differential analog input signals. In single-ended mode, D3..D0 selects the active channel. In differential mode, D2..D0 selects the active channel and (D3 has no affect).

NOTE: The settling time of the multiplexer depends on the resistance.of the input

sources.

 

 

source resistance = about 0.1K ohm

Æ settling time = about 3 us.

source resistance = about 1K ohm

Æ settling time = about 5 us.

source resistance = about 10K ohm

Æ

settling time = about 10 us.

source resistance = about 100K ohm

Æ

settling time = about 100 us.

OME-A-822PGL/PGH Hardware Manual ---- 21

Page 23
Image 23
Omega OME-A822PG manual OME-A-822PGH Gain Control Code Table, 7 A/D Multiplex Control Register