<Digital I/O> Test Screen

zConnect CN1 to CN2

z16 bit up counter is sent to 16 channel DO

z16 channel DO is connected to 16 channel DI

z16 channel DI are readback and show on the screen

zIf DO equals DI then OK shown on screen

zIf DO does not equal DI then Error shown on screen

zPress <p> pause screen, press <p> again release screen

zPress <Up> key to increase the screen delay

zPress <Down > key to decrease the screen delay

zPress <ESC> key to quit