Isolatio n B arrie r

 

mon

 

 

 

Large

com

 

 

 

ode voltage signal

board

 

 

 

m

between

& A/D

 

 





 

source

 

 

 

 

 

G N D

W hen the voltage difference between signal source and A/D board ground is large enough so the A/D board’s comm on m ode range is exceeded, isolated signal conditioning m ust be added.

CH

H igh

+

 

 

 

 

 

 

In p u t

To A /D

 

 

A m p

 

 

 

CH Low

-

 

 

 

10 K

 

 

 

LL GN D

 

 

I/O

 

A/D Board

C onnector

 

10K is a recom m ended valu e . You m ay short LL G N D to C H Low instead, b ut this w ill reduce your system ’s noise im m unity.

System with a Large C om m on Mode Voltage,

Connected to a Differential Input

4.2.6 Isolated Grounds / Single-Ended Inputs

Single-ended inputs can be used to monitor isolated inputs, though the use of the differential mode will increase your system’s noise immunity. The diagram below shows the recommended connections is this configuration.

 

ted

 

 

ola

 

 

l

Is

 

 

 

 

 

 

na

 

 

sig

source

 

 

 

 





 

CH IN

 

LL GND

I/O

C o nn ector

+

Inp ut

 

To A/D

A m p

 

 

 

-

A /D Board

Isolated Signal Source

Connected to a Single-Ended Input

4.2.7 Isolated Grounds / Differential Inputs

Optimum performance with isolated signal sources is assured with the use of the differential input setting. The diagram below shows the recommend connections is this configuration.