RS-232C

$ Time lapse control commands

These commands are not acknowledged while a search control command is being processed.

Data transmitted by PC

Data returned from unit in response

Description of command

 

 

 

 

 

 

 

 

 

[STX] LBR:m [ETX]

[STX] LBR [ETX]

Sets whether the buzzer is to sound when REC REVIEW

Parameter

 

reveals that the proper video level was not maintained.

m = N: Buzzer ON

 

 

F: Buzzer OFF

 

 

 

 

 

 

 

[STX] LBZ:m [ETX]

[STX] LBZ [ETX]

Sets whether the buzzer is to sound during alarm recording

Parameter

 

and sensor recording.

m = N: Buzzer ON

 

 

F: Buzzer OFF

 

 

 

 

 

 

 

[STX] LMS:m [ETX]

[STX] LMS [ETX]

Sets the timing at which to switch the video signals which

Parameter

 

are supplied from the camera and which are to be output

m = 0:

1 second

 

from the rear panel VIDEO OUT connector.

1:

1.5 seconds

 

 

2:

2 seconds

 

 

3:

2.5 seconds

 

 

4:

3 seconds

 

 

5:

4 seconds

 

 

6:

5 seconds

 

 

7:

10 seconds

 

 

 

 

 

 

 

[STX] LDA:m [ETX]

[STX] LDA [ETX]

Sets how the control signals are to be output to the

Parameter

 

component connected to ALARM OUT on the rear panel

m = C: CONTINUE

 

terminal section when alarm recording or sensor recording

 

Control signals continue to

 

is performed.

 

be output even after

 

 

 

recording.

 

 

A: ALARM REC

 

 

 

Control signals are output

 

 

 

only during alarm recording

 

 

 

and sensor recording.

 

 

 

 

 

 

 

[STX] LDF:m [ETX]

[STX] LDF [ETX]

Sets whether field recording or frame recording is to be

Parameter

 

performed for alarm recording and sensor recording.

m = I:

Field recording

 

 

R: Frame recording

 

 

 

 

 

 

 

[STX] LDM:m [ETX]

[STX] LDM [ETX]

Sets what recording is to be performed when an alarm

Parameter

 

signal has been input.

m = F: OFF

 

 

 

Alarm signal input is

 

 

 

ignored.

 

 

M: ALARM/SENSOR

 

 

 

Alarm recording or sensor

 

 

 

recording is performed.

 

 

A: ALARM

 

 

 

Alarm recording is

 

 

 

performed.

 

 

S: SENSOR

 

 

 

Sensor recording is

 

 

 

performed.

 

 

 

 

 

 

76