RS-232C

$ Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

 

 

 

 

 

 

 

 

[STX] QUI [ETX]

 

[STX] LUISdata [ETX]

Queries the setting of the user ID to be recorded.

 

Parameter

 

 

data = U7U6U5U4U7U3U2U1U0

 

 

Sets the user ID to be written using an

 

 

ASCII code.

 

 

Binary 4BITa8

 

 

7

 

 

ASCII code: 0—9, A—F

 

 

 

 

 

[STX] QVC [ETX]

 

[STX] VVCm:data [ETX]

Queries the results of detecting whether the video input

 

Parameter

signals are present.

 

m = A: Execution of detection

<Note>

 

 

processing by VCC command

When the POWER switch is at OFF, the signals are not

 

 

underway

detected, and an error results.

 

S: Detection processing by VCC

Initiate the detection processing using the VVC command

 

 

command completed or

before executing the QVC command.

 

 

detection stopped

Correct results cannot be obtained unless processing has

 

data = c13-16c9-12c5-8c1-4

been completed using the VVC command.

 

c13-16= 1—F:

 

 

Connection information for camera

 

 

No.13—16

 

 

c9-12= 1—F:

 

 

Connection information for camera

 

 

No.9—12

 

 

c5-8 =

1—F:

 

 

Connection information for camera

 

 

No.5—8

 

 

c1-4 =

1—F:

 

 

Connection information for camera

 

 

No.1—4

 

 

<Note>

 

 

 

For details on C¢, refer to the Camera

 

 

connection information table.

 

 

 

 

 

[STX] QVM [ETX]

 

[STX] VMDm [ETX]

Queries the color setting for the video output signals.

 

Parameter

 

 

m = A: AUTO

 

 

 

Color is switched automatically

 

 

 

in accordance with the input

 

 

 

signals.

 

 

B: B/W

 

 

 

Monochrome

 

 

 

 

 

[STX] QWB [ETX]

 

[STX] LWBm [ETX]

Queries the setting for whether the buzzer is to sound when

 

Parameter

a problem occurs in the unit and the power is automatically

 

m = N: Buzzer ON

turned off.

 

F: Buzzer OFF

 

 

 

 

 

[STX] QXT [ETX]

 

[STX] LXTm [ETX]

Queries the setting for whether the signals from the external

 

Parameter

timer connected to the rear panel terminal section are to be

 

m = N: Signals are acknowledged.

acknowledged in the external timer recording mode.

 

F: Signals are not acknowledged.

 

 

 

 

 

100