Useful functions

Alarm memory recall and power loss memory recall

Alarm memory recall is a function for storing in the memory those dates/times and number of occasions on which the alarm recording and sensor recording functions were activated.

Power loss memory recall is a function for storing in the memory those dates/times and number of occasions on which the primary power supply was shut off due to a power outage, etc.

1 2

RESET button

2 1 ∫ ; 4 3

43

<

6 5

H

H

 

2

1

1 Set the POWER switch to ON.

2 Set the PROGRAM switch to the MENU position while holding down the STOP button.

The ALARM RECALL screen and POWER LOSS MEMORY screen now appear.

The alarm number/s and dates/times when the alarm signal was input are displayed on the ALARM RECALL screen.

The number of times the primary power source has been shut off and the dates/times when this happened are displayed on the POWER LOSS MEMORY screen.

(Data is displayed in sequence with the latest at the top of the screen.)

[ALARM RECALL]

 

29

12

– 30 – 2000

3:15

28

12

– 04 – 2000

12:10

27

10

– 25 – 2000

2:20

26

9

– 10 – 2000

2:30

25

8

– 11 – 2000

6:55

24

5

– 10 – 2000

3:22

23

4

– 11 – 2000

6:55

22

3

– 10 – 2000

3:22

[POWER LOSS MEMORY]

 

14

12

– 01 – 2000

12:00

13

10

– 05 – 2000

10:30

12

08

– 10 – 2000

9:20

11

3

– 02 – 2000

7:00

The following display appears when alarm recording was never performed or when the primary power supply was never shut off.

[ALARM RECALL]

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

[POWER LOSS MEMORY]

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

<Notes>

O Data for up to 8 alarms is stored on the ALARM RECALL screen whereas data for up to 4 power losses is stored on the POWER LOSS MEMORY screen.

O A total of 99 alarms and 99 power losses are stored in the memory.

When 99 is exceeded, the count returns to “00.”

O As with alarm recordings, the sensor recordings are stored as alarm memory data.

O The alarm memory data and power loss memory data are stored in the memory circuit inside the unit. They are not recorded on the tape.

O When the PROGRAM switch is set to any position except MENU, the ALARM RECALL screen and POWER LOSS MEMORY screen displays are cleared.

O When the RESET button is pressed while the ALARM RECALL screen is displayed, the memory can be cleared, but the POWER LOSS MEMORY screen is not cleared.

[ALARM RECALL]

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

¢¢ ¢¢¢¢¢¢¢¢ ¢¢:¢¢

[POWER LOSS MEMORY]

 

14

12

– 01

– 2000

12:00

13

10

– 05

– 2000

10:30

12

08

– 10

– 2000

9:20

11

3

– 02

– 2000

7:00

26