RS-232C

$ Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

 

 

 

 

 

 

 

 

 

 

 

 

[STX] QIR [ETX]

 

 

[STX] LUImdata [ETX]

Queries the user ID recorded on the playback tape.

 

Parameter

 

 

 

 

m = R: READ OK

 

 

 

E: READ NG

 

 

data = U7U6U5U4U7U3U2U1U0

 

 

The user ID is returned as an 8-

 

 

character ASCII code.

 

 

Binary 4BITa8

 

 

 

 

7

 

 

 

 

 

ASCII code: 0—9, A—F

 

 

 

 

 

 

[STX] QIW [ETX]

[STX] LIWabcdefgh:ijklmnop [ETX]

Queries the weekly timer and daily timer setting.

 

Parameter

 

 

 

 

a—p =

1—8: Program registration

 

 

 

 

 

number (PGM1—PGM8)

 

 

 

 

F: Timer is not set.

 

 

 

 

 

 

 

 

a = Program

1 on Sunday

 

 

 

 

b = Program

1 on Monday

 

 

 

 

c = Program

1 on Tuesday

 

 

 

 

d = Program

1 on Wednesday

 

 

 

 

e = Program

1 on Thursday

 

 

 

 

f =

Program

1 on Friday

 

 

 

 

g =

Program

1 on Saturday

 

 

 

 

h =

Daily program 1

 

 

 

 

i =

Program

2 on Sunday

 

 

 

 

j =

Program

2 on Monday

 

 

 

 

k =

Program

2 on Tuesday

 

 

 

 

l =

Program

2 on Wednesday

 

 

 

 

m =Program

2 on Thursday

 

 

 

 

n = Program

2 on Friday

 

 

 

 

o = Program

2 on Saturday

 

 

 

 

p = Daily program 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[STX] QLA:m [ETX]

 

 

 

[STX] LAmn [ETX]

Queries the operation mode that is to be established when

Parameter

Parameter

 

 

an alarm signal has been input at the tape-end position, and

m = I: Operation mode

m = I:

Operation mode

the duration of the alarm recording and/or sensor recording.

D: Time setting

 

 

 

 

 

 

 

 

n = S: STOP

 

 

 

 

 

 

 

 

 

 

Stop mode at tape-end

 

 

 

 

 

 

position

 

 

 

 

 

C: CONTINUE

 

 

 

 

 

 

Alarm signal input is

 

 

 

 

 

 

ignored.

 

 

 

 

 

 

 

 

m = D: Time setting

 

 

 

 

 

 

 

 

 

n = 0:

30 seconds

 

 

 

 

 

1:

1 minute

 

 

 

 

 

2:

1 minute and 30 seconds

 

 

 

 

 

3:

2 minutes

 

 

 

 

 

4:

3 minutes

 

 

 

 

 

5:

6 minutes

 

 

 

 

 

6:

10 minutes

 

 

 

 

 

7: CONTINUE

 

 

 

 

 

 

Recording continues until

 

 

 

 

 

 

the tape-end.

 

 

 

 

 

8: MANUAL

 

 

 

 

 

 

Recording is performed only

 

 

 

 

 

 

while an alarm signal is

 

 

 

 

 

 

input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

89