Setting menus

Menu page P7

[TERMINAL INPUT SELECT]

 

P7

TERMINAL INPUT SELECT screen

 

 

 

EXT TIMER IN

OFF

 

 

 

TIME ADJUST IN

9:00

 

Menu item

Description of function

[TERMINAL OUTPUT SELECT]

 

 

 

 

ALARM/SENSOR OUT

CONTINUE

 

 

 

 

EXT TIMER IN

For setting whether the signals from the external timer connected to

ERROR WARN/REC OUT

WARNING

 

EXT TIMER OUT

START 0:00

 

 

the rear panel terminal section are to be acknowledged in the

[VIDEO OUT SEQUENCE]

END 0:00

 

 

external timer recording mode.

2s

 

 

ON : The signals from the external timer are acknowledged.

SW INTERVAL

 

 

OFF : The signals from the external timer are not acknowledged.

BYPASS CAMERA

OFF

 

 

 

 

Select OFF when using an external timer which has been

BLACK MATTE

OFF

 

 

 

 

connected to the unit’s power cord.

LL CAMERA

OFF

 

 

[EXT SWITCHER]

 

 

 

 

 

 

TIME ADJUST IN

For setting the time to be set when signals have been input from the

MODE

VIDEO OUT

 

 

 

component connected to TIME ADJ IN on the rear panel terminal

 

 

 

 

 

 

 

 

section.

 

 

 

 

00:00 to 23:59, RESET

 

 

 

 

Factory setting mode (9:00)

 

 

 

 

<Notes>

 

 

 

 

OThe seconds are fixed at “00.”

 

 

 

 

OWhen signals are input after RESET has been set, the minutes of

 

 

 

 

the time are set to “00.”

 

 

 

 

The minute setting is returned to “00” while it is between 0 and 15

 

 

 

 

minutes when signals are input.

 

 

 

 

The hour is carried up and the minutes are set to “00” while the

 

 

 

 

setting is between 45 and 59 minutes when signals are input.

 

 

 

 

 

 

 

 

 

The underlining indicates the factory mode setting.

TERMINAL OUTPUT SELECT screen

Menu item

 

Description of function

 

 

ALARM/SENSOR

For setting how the control signals are to be output to the component

OUT

connected to ALARM OUT on the rear panel terminal section when

 

alarm recording or sensor recording is performed.

 

CONTINUE : The control signals continue to be output even after

 

 

recording.

 

ALARM REC : The control signals are output only during alarm

 

 

recording or sensor recording.

 

 

ERROR WARN/

For setting how the control signals are to be output to the component

REC OUT

connected to WARNING/REC OUT on the rear panel terminal

 

section when a problem has occurred in the unit.

 

WARNING : The control signals continue to be output.

 

REC

: The control signals are output only during recording.

 

 

EXT TIMER OUT

For setting the START time and END time at which the control

 

signals are to be output to the component connected to EXT TIMER

 

OUT on the rear panel terminal section.

 

0:00—23:59

 

<Note>

 

 

The control signals are not output when the same time has been set

 

for both the START and END times.

 

 

 

The underlining indicates the factory mode setting.

48