RS-232C

$ Mode transition table

 

 

 

 

VTR STATUS

 

 

Return

 

 

REV

STILL/

REC

REC

POWER

command

STOP

 

FF

REW PLAY PLAY

PAUSE

CUE REVIEW PAUSE

REC CHECK EJECT

OFF

 

OPR

±

±

±

±

±

±

±

±

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPL

±

±

±

==

±

±

±

±

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OSP

==

±

±

±

±

±

±

±

±

±

±

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPA

±

±

±

±

±

PLAY

±

±

REC

REC

t

t

t

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORW

±

±

±

±

±

±

±

±

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

±

±

±

±

±

±

±

±

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OAF

t

t

t

t

t

±

t

t

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OAR

t

t

t

t

t

±

t

t

t

t

t

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OEJ

±

±

±

±

±

±

±

±

±

±

±

==

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORR

t

t

t

t

t

t

t

t

t

±

==

t

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORC

±

±

±

±

±

REC

±

±

±

==

±

t

t

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PON

==

==

==

==

==

==

==

==

==

==

==

==

±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POF

±

±

±

±

±

±

±

±

±

±

±

±

==

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Search

±

±

±

±

±

±

±

±

t

t

t

t

t

command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

 

 

 

 

 

±: Operation changes to a return command mode.

t: Error code ERE is returned, and command execution is disabled. : The operation status is retained.

OPA command : This command may cause the unit to transfer from its current operation mode to a different operation mode.

Search commands : OPT, SCP, SCS, SMS, SPT, SRS, SUB