Terminal connections

As shown below, firmly twist the end of the cord which is to be connected to the terminal section.

Firmly twist or solder here.

Solid wire : 0.4 to 1.2 mm diameter

Twisted wire : 0.3 to 1.25 mm

(The diameter of the strands must be 0.18 mm or more.)

When connecting or disconnecting the cord, press this part down using a regular screwdriver.

O Failure to twist the end of the cord firmly can cause short-circuiting.

Alarm recording connections

Alarm switch 1

Alarm switch 2

When an alarm signal is input to

When an alarm signal is input to

ALARM IN 1, alarm recording or

ALARM IN 2, alarm recording or

sensor recording is performed.

sensor recording is performed.

 

External alarm lamp

Alarm reset

External alarm buzzer

 

switch

External interface

 

+

 

4V to 5V

 

1

2 GND

IN OUT

WARNING

IN

RESET OUT

EXT

/REC OUT

 

ALARM

TIMER

TAPE END OUT

 

REC IN GND

TIME ADJ IN

O When alarm recording has been set for MODE on the menu screen shown on P4 ALARM/SENSOR REC, alarm recording is started when the alarm switch is set to ON.

O Alarm recording is released when the alarm reset switch is set to ON.

35