Chapter 6 Maintenance and inspections
5. HUMID
Indications on LCD screen | “HUMID” display lights if condensation is |
| detected. |
| “HUMID” display flashes for an additional 10 to 90 |
| minutes after condensation detection is canceled. |
|
|
WARNING lamp | Lights for 90 minutes following the release of the |
| condensation detection after the condensation |
| formation was detected. |
|
|
Tally lamp | Flashes 4 times per second for 90 minutes after |
| condensation detection is canceled. |
|
|
Viewfinder | “HUMID” display flashes from the time |
| condensation is detected until 90 minutes after |
| the condensation detection is released. |
|
|
Alarm | Sounds continuously (4 times a second during |
| recording). |
|
|
Warning description | Condensation has formed. |
|
|
VTR unit operation | The recording operation continues but if the tape |
| sticks, recording will stop. |
| For 80 minutes after the condensation detection is |
| released, the drum is rotated and no operations |
| are accepted. |
|
|
Corrective action | Stop the tape travel and turn off the power. If the |
| “HUMID” display fails to be cleared even when the |
| power is turned back on, wait until it clears. |
|
|
6. SERVO
Indications on LCD screen | “SERVO” display lights (during recording and |
| playback). |
|
|
WARNING lamp | Flashes four times a second (during recording |
| and playback). |
|
|
Tally lamp | Flashes four times a second (during recording |
| and playback). |
|
|
Viewfinder | “SERVO” display lights (during recording and |
| playback). |
|
|
Alarm | Sounds four times a second (during recording and |
| playback). |
|
|
Warning description | The servo is disturbed. |
|
|
VTR unit operation | Operation continues but the unit may not operate |
| correctly. |
|
|
Corrective action | Turn off the power and consult your dealer. The |
| warning display may flash for a moment and then |
| disappear when tape transport commences: this |
| is normal and not indicative of a failure or |
| malfunctioning. |
|
|
7. RF
Indications on LCD screen | “RF” display flashes (during standby and recording). |
|
|
|
|
|
|
WARNING lamp | Flashes four times a second (during recording). |
|
|
|
|
|
|
Tally lamp | Flashes four times a second (during recording). |
|
|
|
|
|
|
Viewfinder | “RF” display lights (during recording). |
|
|
|
|
|
|
Alarm | Sounds four times a second (during recording). |
|
|
|
|
|
|
Warning description | The video heads have become clogged. There is |
|
|
| a problem in the video system. |
|
|
|
|
|
|
VTR unit operation | The cleaning rollers are activated to clean the |
|
|
| heads (for a maximum of 10 seconds). |
|
|
| Recording continues but the signals may not be |
|
|
| recorded correctly. |
|
|
| The indications on LCD screen are retained until |
|
|
| the REC/PAUSE status is established. They go |
|
|
| off as soon as the unit transfers from the |
|
|
| 6 | ||
| REC/PAUSE mode to another mode. |
| |
|
|
| |
Corrective action | Clean the heads. If the signals cannot be |
| |
| recorded correctly even after cleaning, consult |
|
|
| your nearest service center. |
|
|
|
|
|
|
8. 1394 |
|
|
|
|
|
| |
Indications on LCD screen | “1394 |
|
|
|
|
|
|
WARNING lamp | Flashes four times a second (during recording). |
|
|
|
|
|
|
Tally lamp | Flashes four times a second (during recording). |
|
|
|
|
|
|
Viewfinder | O When error code 92 appears, “1394 INITIAL |
|
|
| ERROR” display lights (during standby and |
|
|
| recording). |
|
|
| O With all other error codes or when 1394 is |
|
|
| selected as the REC SIGNAL menu item |
|
|
| setting, the error is not displayed in the |
|
|
| viewfinder. |
|
|
|
|
|
|
Alarm | Sounds four times a second (during recording). |
|
|
|
|
|
|
Warning description | There is something wrong with the signals |
|
|
| supplied to the DVCPRO connector. |
|
|
|
|
|
|
VTR unit operation | Operation continues, but something is wrong with |
|
|
| the signals supplied to the DVCPRO connector. |
|
|
|
|
|
|
Corrective action | Check the IEEE 1394 cable and DVCPRO |
|
|
| connector connections and the settings of the |
|
|
| external units or menu settings, and then turn the |
|
|
| power off and back on. |
|
|
| If the warning display is not cleared, check |
|
|
| Error codes,” and consult your nearest service |
|
|
| center. |
|
|
|
|
|
|
9. WIRELESS RF |
| ||
|
|
| |
Indications on LCD screen | No indication |
|
|
|
|
|
|
WARNING lamp | Flashes four times a second (during standby and |
|
|
| recording). |
|
|
|
|
|
|
Tally lamp | Flashes four times a second (during recording). |
|
|
|
|
|
|
Viewfinder | “WIRELESS RF” display lights for at least 3 |
|
|
| seconds during recording. |
|
|
|
|
|
|
Alarm | Sounds four times a second (for at least 3 |
|
|
| seconds during standby and recording). |
|
|
|
|
|
|
Warning description | Poor wireless signal reception. |
|
|
|
|
|
|
VTR unit operation | Operation continues but the signals from the |
|
|
| wireless microphone cannot be received. |
|
|
|
|
|
|
Corrective action | Check the microphone’s power supply and the |
|
|
| reception condition of the receiver. |
|
|
|
|
|
|
77