Chapter 7 Menu description tables

7-3-9 KNEE/LEVEL

 

Item/

 

Variable

Remarks

Data storage

range

 

 

 

 

 

 

 

 

 

MASTER PED

 

–200

For performing the MASTER PEDESTAL

 

 

 

 

 

 

:

setting.

 

 

 

 

 

 

+010

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

S

C

U

F

 

E

+200

 

$ MANUAL KNEE

 

ON

For setting the mode which is to be established

 

 

 

 

 

 

OFF

when the AUTO KNEE switch is at OFF. The

 

 

 

 

 

 

 

KNEE POINT/SLOPE setting value is active

S

C

U

F

E

 

when ON is selected.

 

 

 

 

 

 

 

 

KNEE POINT

 

70.0%

For setting the KNEE POINT position in 0.5%

 

 

 

 

 

 

:

steps.

 

 

 

 

 

 

85.0%

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

S

C

U

F

E

107.0%

 

 

 

 

 

 

 

 

 

KNEE SLOPE

 

00

For performing the KNEE width setting.

 

 

 

 

 

 

:

Same as KNEE OFF when set to 0.

 

 

 

 

 

 

50

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

:

 

 

 

 

 

 

99 (98)

The range of values that can be selected

 

 

 

 

 

 

 

using the AJ-EC3E is 00 to 98.

S

C

U

F

E

 

 

 

 

 

 

 

 

 

 

 

$ WHITE CLIP

 

ON

For selecting ON or OFF for the WHITE CLIP

 

 

 

 

 

 

OFF

function. The WHITE CLIP LVL setting value

S

C

U

F

E

 

is active when ON is selected.

 

 

 

 

 

 

 

 

WHITE CLIP LVL

 

90%

For performing the WHITE CLIP LEVEL

 

 

 

 

 

 

:

setting.

 

 

 

 

 

 

105%

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

S

C

U

F

E

109%

 

 

 

 

 

 

 

 

 

A.KNEE POINT

 

80%

For setting the AUTO KNEE POINT position

 

 

 

 

 

 

:

in 0.5% steps. This item is active when the

 

 

 

 

 

 

85%

 

 

 

 

 

 

OUTPUT/AUTO KNEE selector switch is set

 

 

 

 

 

 

:

S

C

U

F

E

107%

to CAM.AUTO KNEE ON.

 

 

 

 

 

 

 

 

A.KNEE LVL

 

100

For performing the AUTO KNEE level setting.

 

 

 

 

 

 

:

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

:

 

S

C

U

F

E

109

 

A.KNEE

 

1

For setting the AUTO KNEE response speed.

RESPONSE

 

:

 

 

4

 

 

 

 

 

 

 

 

S

C

U

F

 

E

 

 

 

 

 

 

 

 

 

 

7-3-10 GAMMA

Item/

Variable

Remarks

Data storage

range

 

 

 

 

MASTER GAMMA

0.35

For setting the MASTER GAMMA in 0.01

 

:

steps.

 

0.45

 

 

 

:

 

SU F E 0.75

R GAMMA

 

 

–15

For setting the R channel GAMMA.

 

 

 

 

:

 

 

 

 

 

+00

 

 

 

 

 

 

:

 

S

C

U

F

E +15

 

B GAMMA

 

 

–15

For setting the B channel GAMMA.

 

 

 

 

:

 

 

 

 

 

+00

 

 

 

 

 

 

:

 

S

C

U

F

E +15

 

7-3-11 FLARE

 

 

7

 

 

 

 

 

 

 

 

 

 

Item/

 

 

Variable

Remarks

 

 

 

 

 

 

Data storage

range

 

 

 

 

 

 

 

 

 

 

 

 

 

R FLARE

 

 

000

For performing the R FLARE setting.

 

 

 

 

 

 

 

 

:

 

 

 

S

C

U

 

F

E

100

 

 

 

 

 

 

 

 

 

 

 

 

G FLARE

 

 

000

For performing the G FLARE setting.

 

 

 

 

 

 

 

 

:

 

 

 

S

C

U

 

F

E

100

 

 

 

 

 

 

 

 

 

 

 

 

B FLARE

 

 

000

For performing the B FLARE setting.

 

 

 

 

 

 

 

 

:

 

 

 

S

C

U

 

F

E

100

 

 

 

 

 

 

 

 

 

 

 

 

 

<Note>

Items with $ in front of their names are set by the PAINT MENU SW ($) R/W menu items on the <CARD R/W SELECT> screen.

Items without $ in front of their names are set by the PAINT MENU LEVEL R/W menu item.

For details, refer to “7-6-2 CARD R/W SELECT.”

The underlining in the variable range column indicates the setting in the preset mode.

89

Page 89
Image 89
Panasonic AJ- E operating instructions Knee/Level, Flare, For setting the Master Gamma, Steps