27
Press the MENU-UP button or MENU-DOWN
button to move the cursor to the NO position,
and press the SET button.
The menu protection mode is now released.
3
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is now set to the menu protection mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the unit is not set to the
menu setting mode, and MENU PROTECTED
appears on the video monitor screen.
<Note>
If, during the setting of the menu protection
mode, the LOCAL/MENU/REMOTE switch is set
to the MENU position while the COUNTER button
on the front panel is held down, the unit is set to
the menu setting mode, and the regular menu
settings can be performed.
Perform steps 2to 7of Setting method using
the on-screen menus.
5
Setup (initial settings)
Releasing the menu protectionmode
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the
COUNTER button on the front panel.
The unit is set to the menu setting mode, and the
menu screen appears on the video monitor.
1
2
MENU PROTECT OK?
2NO
YES
Perform steps 2and 3of the menu protection
procedure described above.
The screen prompting the user to confirm
whether to initiate menu protection appears on
the video monitor.
Displaying the DIAG menu
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is set to the DIAG display mode, and the
hour meter and deck serial No. appear on the
video monitor.
1
Items with rcan be reset when the unit is
serviced.
DIAGMENU HOURS METER
Ser 222222222
H00 OPERATION 00000H
H01 DRUM RUN 00000H
H02 TAPE RUN 00000H
H03 THREADING 00000T
H04 F LOADING 00000T
H11 DRUM RUN r 00000H
H12 TAPE RUN r 00000H
H13 THREADING r 00000T
H14 F LOADING r 00000T
With the hour meter displayed, press the
SEARCH button.
The software version appears on the video
monitor.
2
The hour meter display is restored when the
SEARCH button is pressed again.
DIAGMENU SOFT VERSION
SYSIF 1.22-22-2.22
AVDV 1.22-22-2.22
SERVO 1.22-22-2.22
END
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is restored to its regular mode.
3
The unit comes with a function for displaying the hour
meter, software version and deck serial No. on the
video monitor.