Error messages

When something goes wrong with the unit, one of the following error messages will appear on the front panel’s counter display and on the monitor’s superimposed display.

With a superimposed display, the error number will appear in the counter value display area.

If T&S&M is selected as the menu item No.006 [DISPLAY SEL] setting, the error messages will appear in the mode display area of the superimposed display.

Error No.

Error message and description

 

 

 

DEW

 

When dew (condensation) has been detected, the

 

error number flashes, and the unit is transferred to

 

the EJECT mode. In the EJECT mode, the tape is

 

ejected, and no further tape operations can be

 

performed.

 

After the tape has been ejected, the cylinder

 

continues to rotate in order to dry out the

 

condensation. When the condensation has dried

 

out, the error display is cleared, and the VTR can be

– d –

operated again.

O If condensation is detected in the EJECT mode,

 

 

the cylinder starts rotating straight away.

 

O If condensation is detected when a cassette is

 

inserted, the cylinder stops rotating, and after the

 

tape has been ejected, it resumes rotating.

 

Wait with power supplied to the unit until the

 

condensation has dried out. When ON is selected

 

as the menu item No.152 [HUMID OPE] setting, the

 

unit can still be operated.

 

The counter value and “– – d – –” appear alternately

 

on the front panel’s counter display area.

 

 

 

SERVO NOT LOCKED

E – 00

This appears when the servo is not locked for 3 or

 

more seconds during playback or recording.

 

 

 

LOW RF

E – 01

This appears when there is no head output (due to

clogging, for instance) for 1 or more seconds during

 

 

playback.

 

 

 

HIGH ERROR RATE

E – 02

This appears when the error rate has deteriorated,

and either the video or audio playback signals are

 

 

subject to correction or interpolation.

 

 

 

NO RF

 

This appears when a blank area on the tape has

 

been detected for 1 or more seconds during

 

playback.

E – 09

The unit recognizes an area on the tape as blank

when all the conditions below are satisfied.

 

 

O There are no output signals from any of the

 

heads.

 

O Playback data cannot be read.

 

O No CTL signal is present.

 

 

 

FAN STOP

 

This appears when the fan motor has stopped

E – 10

operating.

 

The unit’s power is automatically turned off in about

 

five minutes after the motor has shut down.

 

 

Error No.

Error message and description

 

 

 

INVALID TC MODE (in 23/24 Hz mode)

 

This appears during playback if the time code is

 

recorded in the DF mode. The video output is

 

disrupted and the sound output is muted at the time

E – 93

code drop points.

The VTR continues to operate.

 

 

If a tape recorded using a variable frame rate

 

camera is to be played back with the unit, the time

 

code must be recorded in the non-drop frame (NDF)

 

mode.

 

 

 

TC SEQUENCE UNMATCH

 

(in 23/24 Hz mode and 25 Hz mode)

 

This appears during playback when the correlation

 

between the active frame information and time code

 

is not correct. The video output may not be uniform

 

(it may not move smoothly).

E – 94

The VTR continues to operate.

 

The information of the active frame (first frame

 

where the frame image is switched) is recorded on

 

tapes which have been recorded using a variable

 

frame rate camera. When playing back these tapes

 

in the unit, frame 0 of the time code must be

 

detected at the active frame position.

 

 

 

FRONT LOAD MOTOR

 

This appears when the cassette has failed to move

 

up even six seconds after the unit has been

 

transferred to the EJECT mode.

E – 29

<Note>

 

If the cassette fails to move down even when six

 

seconds has elapsed after the cassette was

 

inserted, the unit will be transferred to the EJECT

 

mode.

 

 

 

LOADING MOTOR

 

This appears when the unloading operation fails to

 

be completed within 6 seconds.

E – 31

<Note>

 

If the loading operation fails to be completed within

 

six seconds after the cassette was inserted, the unit

 

will be transferred to the EJECT mode.

 

 

 

SERVO CONTROL ERROR

E – 35

This appears when there has been no response

 

from the servo microcomputer for 1 second or more.

 

 

 

SERVO COMM ERROR

E – 37

This appears when the servo microcomputer fails to

carry out an instruction of the system control

 

 

microcomputer even after 10 seconds have elapsed.

 

 

 

SERVO FG ERROR

 

This appears when the automatic reel and capstan

E – 38

rotation adjustment, which is performed in the

 

EJECT mode, has not been carried out properly

 

when the unit’s power was switched on.

 

 

50

Page 50
Image 50
Panasonic AJ-HD1200A Error messages, Error No Error message and description, 23/24 Hz mode and 25 Hz mode