Table of AUTO OFF Error messages
Counter display | Monitor display |
|
|
|
|
|
|
| Description |
|
|
|
|
|
|
| VTR operation |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Restart condition) |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
CAP ROTATE TOO | CAP ROTA TOO | If | the | capstan | motor | speed | is | abnormally | low, the | STOP |
|
| |||||||||||
SLOW | SLOW | AUTO | OFF | lamp | lights, | and | the | message | display |
| → |
| |||||||||||
| (POWER OFF | ON) | |||||||||||||||||||||
flashes. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
CAP TENSION ERROR | CAP TENSION ERROR | If | an | abnormal | tension at the | supply side | is | detected |
| STOP |
|
| |||||||||||
|
| in the capstan mode, the AUTO OFF lamp lights, and |
|
|
| → |
| ||||||||||||||||
|
|
|
|
| (POWER OFF | ON) | |||||||||||||||||
|
| the message display flashes. |
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| ||||||||||||||||
DEW | DEW | If | condensation is detected, the AUTO OFF lamp |
| EJECT |
|
| ||||||||||||||||
|
| lights, | the | message | display |
| flashes, | and | the | VTR | is |
|
|
| |||||||||
|
| transferred | to | the | eject |
| mode. | After | the | tape | is | (Normal operation |
|
| |||||||||
|
| ejected, the drum | rotates | in | order | to | eliminate the |
| resumed after |
|
| ||||||||||||
|
| condensation. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| condensation is |
|
| ||||
|
| When | the condensation | has |
| been | eliminated, |
| the |
| eliminated) |
|
| ||||||||||
|
| AUTO OFF lamp and message display go off, and the |
|
|
|
|
|
| |||||||||||||||
|
| VTR can be used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| <Notes> |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 1) | If condensation is detected in the eject mode, the |
|
|
|
| ||||||||||||||||
|
| 2) | drum starts rotating as soon as it is detected. |
|
|
|
| ||||||||||||||||
|
| If condensation is detected when the cassette has |
|
|
|
| |||||||||||||||||
|
|
|
| been inserted, the drum rotation is stopped, and |
|
|
|
| |||||||||||||||
|
|
|
| after the tape is ejected, the drum starts rotating. |
|
|
|
| |||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
DRUM ROTATE TOO | DRUM ROTA TOO | If the cylinder motor speed is abnormally high, the | STOP |
|
| ||||||||||||||||||
AUTO | OFF | lamp | lights, | and | the | message | display |
|
|
| |||||||||||||
FAST | FAST |
| (POWER OFF | → | ON) | ||||||||||||||||||
flashes. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
DRUM ROTATE TOO | DRUM ROTA TOO | If | the | cylinder | motor speed | is | abnormally | low, | the | STOP |
|
| |||||||||||
SLOW | SLOW | AUTO | OFF | lamp | lights, | and |
| the | message | display |
| (POWER OFF | → | ON) | |||||||||
|
| flashes. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
If | the tape start and tape | end are detected simulta- |
| STOP |
|
| |||||||||||||||||
|
| neously | either during | or | after |
| loading, | the AUTO OFF |
|
| (POWER OFF | → | ON) | ||||||||||
|
| lamp lights, and the message display flashes. |
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||||
FRONT LOAD ERROR | FRONT LOAD ERROR | The | AUTO OFF lamp lights and the message display |
|
|
|
|
|
| ||||||||||||||
|
| flashes when | the | has been rotating | idly |
| STOP |
|
| ||||||||||||||
|
| for | a | fixed | period | of |
| time | while | the |
| start/end | → |
| |||||||||
|
|
|
| (POWER OFF | ON) | ||||||||||||||||||
|
| processing operation during loading (half position) is |
| ||||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
|
| being performed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
FRONT LOAD MOTOR | FRONT LOAD MOTOR | If | the | cassette | does | not |
| move up even when 6 |
|
|
|
| |||||||||||
|
| seconds have elapsed since the VTR was transferred |
|
|
|
|
|
| |||||||||||||||
|
| to the eject mode, the AUTO OFF lamp lights, and the |
|
|
|
|
| ||||||||||||||||
|
| message display flashes. |
|
|
|
|
|
|
|
|
|
| STOP |
|
| ||||||||
|
| <Note> |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| → |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (POWER OFF | ON) | |||||
|
| If | the | cassette | does | not |
| move | down | inside | the |
| |||||||||||
|
|
|
|
|
|
| |||||||||||||||||
|
| machine even when 6 seconds | have | elapsed | since |
|
|
|
|
| |||||||||||||
|
| the | cassette was inserted, the VTR | is | transferred | to |
|
|
|
| |||||||||||||
|
| the eject mode. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||||||||||||||
LOADING MOTOR | LOADING MOTOR | When the unloading operation is not completed within |
|
|
|
|
| ||||||||||||||||
|
| 6 | seconds, | the | AUTO | OFF | lamp | lights, | and | the |
|
|
|
| |||||||||
|
| message display flashes. |
|
|
|
|
|
|
|
|
|
| STOP |
|
| ||||||||
|
| <Note> |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| → |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (POWER OFF | ON) | |||||
|
| When the loading operation is not completed within 6 |
| ||||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
|
| seconds, the VTR is transferred to the eject (unload- |
|
|
|
| |||||||||||||||||
|
| ing) mode. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 106 –