Table of AUTO OFF Error messages

Counter display

Monitor display

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

VTR operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Restart condition)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP ROTATE TOO

CAP ROTA TOO

If

the

capstan

motor

speed

is

abnormally

low, the

STOP

 

 

SLOW

SLOW

AUTO

OFF

lamp

lights,

and

the

message

display

 

 

 

(POWER OFF

ON)

flashes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP TENSION ERROR

CAP TENSION ERROR

If

an

abnormal

tension at the

supply side

is

detected

 

STOP

 

 

 

 

in the capstan mode, the AUTO OFF lamp lights, and

 

 

 

 

 

 

 

 

 

(POWER OFF

ON)

 

 

the message display flashes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEW

DEW

If

condensation is detected, the AUTO OFF lamp

 

EJECT

 

 

 

 

lights,

the

message

display

 

flashes,

and

the

VTR

is

 

 

 

 

 

transferred

to

the

eject

 

mode.

After

the

tape

is

(Normal operation

 

 

 

 

ejected, the drum

rotates

in

order

to

eliminate the

 

resumed after

 

 

 

 

condensation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

condensation is

 

 

 

 

When

the condensation

has

 

been

eliminated,

 

the

 

eliminated)

 

 

 

 

AUTO OFF lamp and message display go off, and the

 

 

 

 

 

 

 

 

VTR can be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Notes>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

If condensation is detected in the eject mode, the

 

 

 

 

 

 

2)

drum starts rotating as soon as it is detected.

 

 

 

 

 

 

If condensation is detected when the cassette has

 

 

 

 

 

 

 

 

been inserted, the drum rotation is stopped, and

 

 

 

 

 

 

 

 

after the tape is ejected, the drum starts rotating.

 

 

 

 

 

 

 

 

 

 

DRUM ROTATE TOO

DRUM ROTA TOO

If the cylinder motor speed is abnormally high, the

STOP

 

 

AUTO

OFF

lamp

lights,

and

the

message

display

 

 

 

FAST

FAST

 

(POWER OFF

ON)

flashes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRUM ROTATE TOO

DRUM ROTA TOO

If

the

cylinder

motor speed

is

abnormally

low,

the

STOP

 

 

SLOW

SLOW

AUTO

OFF

lamp

lights,

and

 

the

message

display

 

(POWER OFF

ON)

 

 

flashes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-FF

E-FF

If

the tape start and tape

end are detected simulta-

 

STOP

 

 

 

 

neously

either during

or

after

 

loading,

the AUTO OFF

 

 

(POWER OFF

ON)

 

 

lamp lights, and the message display flashes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT LOAD ERROR

FRONT LOAD ERROR

The

AUTO OFF lamp lights and the message display

 

 

 

 

 

 

 

 

flashes when

the

take-up reel

has been rotating

idly

 

STOP

 

 

 

 

for

a

fixed

period

of

 

time

while

the

 

start/end

 

 

 

 

 

(POWER OFF

ON)

 

 

processing operation during loading (half position) is

 

 

 

 

 

 

 

 

 

being performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT LOAD MOTOR

FRONT LOAD MOTOR

If

the

cassette

does

not

 

move up even when 6

 

 

 

 

 

 

seconds have elapsed since the VTR was transferred

 

 

 

 

 

 

 

 

to the eject mode, the AUTO OFF lamp lights, and the

 

 

 

 

 

 

 

message display flashes.

 

 

 

 

 

 

 

 

 

 

STOP

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(POWER OFF

ON)

 

 

If

the

cassette

does

not

 

move

down

inside

the

 

 

 

 

 

 

 

 

 

 

machine even when 6 seconds

have

elapsed

since

 

 

 

 

 

 

 

the

cassette was inserted, the VTR

is

transferred

to

 

 

 

 

 

 

the eject mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOADING MOTOR

LOADING MOTOR

When the unloading operation is not completed within

 

 

 

 

 

 

 

6

seconds,

the

AUTO

OFF

lamp

lights,

and

the

 

 

 

 

 

 

message display flashes.

 

 

 

 

 

 

 

 

 

 

STOP

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(POWER OFF

ON)

 

 

When the loading operation is not completed within 6

 

 

 

 

 

 

 

 

 

seconds, the VTR is transferred to the eject (unload-

 

 

 

 

 

 

ing) mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 106 –