Setup menus
This VTR can hold five user files, each of which has its own specific menu settings, and one of these files can be selected for use.
Changing the file
1 Press the MENU (SHIFT+RECORDER).
2 When the FF button is pressed while holding down the SHIFT button, the next user file is selected; conversely, when the REW button is pressed while holding down the SHIFT button, the previous user file is selected.
Setting and releasing the lock mode
The lock mode can be set to protect the system file and user file (USER2 to USER5) settings. Once the lock mode is set, no further changes can be made to the settings.
Setting and releasing the lock mode can be set for the system file by using setup menu No. 30 (MENU LOCK) and for the user files by using setup menu No. A03 (MENU LOCK).
1 Press the MENU (SHIFT+RECORDER).
2 Press the REW button or FF button while holding
SYSTEM
FF REW
| USER 1 | ||
| FF |
| REW |
|
| ||
|
|
|
|
| USER 2 | ||
|
|
| |
REW FF | FF |
| REW |
| |||
|
|
| |
| USER 3 | ||
|
|
| |
| FF |
| REW |
|
| ||
|
|
|
|
| USER 4 | ||
|
|
| |
| FF |
| REW |
|
| ||
|
|
|
|
USER 5
User files
Each user file contains the following items.
OBASIC
OOPERATION O INTERFACE O EDIT
O TAPE PROTECT O TIME CODE
O VIDEO O AUDIO O V BLANK O MENU
down the SHIFT button to select the file for which the lock mode is to be set or released.
3 Turn the search dial to move the cursor (2) on the menu screen to No. 30 (MENU LOCK) for the system file or to No. A03 (MENU LOCK) for a user file.
4 Turn the search dial while holding down the search button to select whether the lock mode is to be set or released.
To set the lock mode:
Set 0001 (ON) as the setting.
To release the lock mode:
Set 0000 (OFF) as the setting.
3 To enter the selection made in step 2 for the user file which is to be used, press the SET button.
The user file is changed and stored in the memory.
<Note>
Since the SYSTEM menu items are not included in user files 1 through 5, first select the user file and switch to the SYSTEM file, and then set the SYSTEM menu items.
When the lock mode has been set, “LOCKED” flashes on the menu screen. The counter display stops flashing and remains lit.
LOCKED |
| |||
<USER2> | NO.000- | 0005 | ||
2000 |
| 5s | ||
001 | LOCAL ENA | ST&EJ | ||
002 | TAPE TIMER | ±12h | ||
003 | REMAIN SEL |
| OFF | |
004 | SETUP NUMBER |
| OFF | |
005 | METER SELECT |
| CUE | |
006 | SYNCHRONIZE |
| ON | |
007 | SUPER |
|
| ON |
008 | DISPLAY SEL | T&STA |
5 Press the SET button.
The setting is stored in the memory.
<Notes>
O The lock mode cannot be set for the USER1 file.
O Once set to the lock mode, a file cannot be reset to the factory settings even by pressing the RESET button.
35