Panasonic AJ-SD965 Reel Rota VTR Stop TOO Fast, Torque ERR VTR Stop, CAP Tension, Reel Tension

Models: AJ-SD965

1 86
Download 86 pages 29.09 Kb
Page 75
Image 75

Error messages (continued)

Error messages

Display

ODescription

 

 

 

OVTR operation and corrective action

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally

 

high, the error number flashes on the display.

S REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally

 

high, the error number flashes on the display.

T REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-69

If excess torque being applied to the take-up

 

reel motor is detected, the error number flashes

T REEL

on the display.

 

 

 

TORQUE ERR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-70

If excess torque being applied to the supply reel

 

motor is detected or an abnormal current flowing

S REEL

to the current detection resistor is detected, this

TORQUE ERR

error number flashes on the display.

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-71

If abnormal tension at the supply side is

 

detected in the capstan mode, the error number

CAP TENSION

flashes on the display.

 

 

ERROR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-72

If abnormal tension at the supply side is

 

detected in the reel mode, the error number

REEL TENSION

flashes on the display.

 

 

ERROR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the

 

reverse direction, this error number flashes on

REEL DIR

the display.

 

 

 

UNMATCH

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-74

If excess torque being applied to the cylinder

 

motor is detected, this error number flashes on

DRUM

the display.

 

 

 

TORQUE

VTR: STOP

 

 

 

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-78

If a problem has been encountered in

 

communication

between

the

servo

SVDR COMM

microcomputer and servo drive board, this error

ERROR

number flashes on the display.

 

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

 

 

 

Consult your dealer if the error message is still displayed even after restarting the unit.