Error messages (continued)

Warning messages

Priority

OMonitor display

ODescription

 

 

 

OVTR operation and corrective action

 

 

 

 

 

 

 

 

High

E-10 (FAN STOP)

 

 

 

This is displayed when the fan motor stops.

 

 

 

VTR: Operation continues.

 

 

 

OCheck that nothing is obstructing the fan

 

 

 

movement.

 

 

 

 

 

 

 

E-09 (NO RF)

 

 

 

This appears during playback when a blank section

 

 

 

(tape blank) lasting for one or more seconds has

 

 

 

been detected.

 

 

 

Such a section is identified as a tape blank when all

 

 

 

of the following conditions are met.

 

 

 

ONo head outputs

 

 

 

ONo playback data readout

 

 

 

ONo CTL (Excluding DV and DVCAM tapes)

 

 

 

VTR: Operation continues.

 

 

 

OCheck the tape.

 

 

 

A tape on which material has not been recorded

 

 

 

may have been inserted.

 

 

 

 

 

 

 

E-00 (SERVO NOT LOCKED)

 

 

 

This appears when the servo is not locked for three

 

 

 

or more seconds during playback, recording, or

 

 

 

editing.

 

 

 

VTR: Operation continues.

 

 

 

OCheck the tape.

 

 

 

A tape recorded other than PAL format may have

 

 

 

been inserted.

 

 

 

 

 

 

 

E-01 (LOW RF)

 

 

 

This appears when envelope levels approximately

 

 

 

1/3 that of normal levels are detected for more than

 

 

 

one second during playback, recording, or editing.

 

 

 

VTR: Operation continues.

 

 

 

OClean the video heads.

 

 

 

 

 

 

 

E-02 (HIGH ERROR RATE)

 

 

 

This appears when the error rate has increased to

 

 

 

the extent that correction or interpolation was

 

 

 

performed on either the video or audio signals.

Low

VTR: Operation continues.

OClean the video heads.

 

 

 

 