4-2-3 Placing the Camera-recorder in
SYNCHRO SCAN Mode
To place the
1Press the SHUTTER switch positioned at [ON] towards [SEL], to place the
SYNCHRO SCAN ADJUSTMENT buttons
SHUTTER switch
2In SYNCHRO SCAN mode, the speed can be switched seamlessly between 1/50.4 and 1/248.0 seconds, using the SYNCHRO SCAN ADJUSTMENT buttons
4-3 Selecting Recording Signals
and Recording System
The
4-3-1 Selecting the Recording Signals.
Signals to be recorded are selected through the menu options REC SIGNAL and CAMERA MODE. These options are found in the <SYSYTEM MODE> screen, which is accessible from the SYSTEM SETTING page.
J
Setting options and usage
The option REC SIGNAL is used to select signals to be recorded.
CAM: Signals from the camera are recorded.
VIDEO: Signals from the GENLOCK IN connector are recorded.
1394: Signals from the DVCPRO/DV connector are recorded. (when the optional board 1394 is attached).
The option CAMERA MODE is used to specify the operation mode of the camera. (effective when the menu option REC SIGNAL is set to “CAM”).
50i:
25P:
To operate the camera in 25P mode, the vertical resolution mode must be selected through the menu option V.RES (25P). (effective when the menu option REC SIGNAL is set to “CAM”).
INTRLCE:
PROG.: Non
Note that in progressive (25P) mode signals recorded on P2 cards are also converted from progressive scan (25P) to interlaced scan (50i).
34