| Information Item | Indication | Status |
|
|
|
|
|
|
|
|
|
|
| P2 card remaining | ___min | The indication “___min” stays illuminated under normal conditions or blinks when |
|
|
|
|
|
| |||
|
| free space | END | the remaining level is near zero. |
|
|
|
|
|
| |||
|
| When the card space is used up, “END” comes on. |
|
| ||
|
|
|
|
| ||
|
|
| WP | The P2 card is |
|
|
|
|
| LOOP | The |
|
|
|
|
|
| performed, for example because the P2 card has no free space, the indication |
|
|
|
|
|
| blinks. |
|
|
|
|
| INFO P2 | P2 card being recognised. |
|
|
|
|
| _/_ | Total free space/capacities of the P2 cards (when MODE CHECK is being |
|
|
|
|
|
| performed). |
|
|
|
|
|
| <Note> |
|
|
|
|
|
| When the menu option P2 CARD REMAIN is set to “ONE CARD”, the number of |
|
|
|
|
|
| the P2 card slot that contains the target card is indicated, together with the |
|
|
|
|
|
|
| ||
|
|
|
| remaining space. |
| 4 |
|
|
|
| For more information, see [P2 Card Remaining Free Space/capacity Indication] on |
| |
|
|
|
| the next page. |
|
|
|
| P2 card remaining | ___min | The number of the P2 card slot that contains the target card and the remaining free |
|
|
|
| free space (when |
| space (when MODE CHECK is being performed) are indicated. In LOOP REC |
|
|
|
|
|
|
| ||
|
|
| mode, the minimum guaranteed recording time is indicated. This indication also |
|
| |
|
| MODE CHECK is |
|
|
| |
|
|
| appears when the target P2 card has been switched with a user button. |
|
| |
|
| being performed) |
| The minimum guaranteed recording time refers to the sum, at the time loop |
|
|
|
|
|
| recording is stopped, of the remaining free space of available P2 cards, except for |
|
|
|
|
|
| the card with the largest remaining free space. |
|
|
|
|
|
| Example: If three P2 cards are available, with remaining space of eight minutes, |
|
|
|
|
|
| five minutes and two minutes respectively, then the minimum |
|
|
|
|
|
| guaranteed recording time is seven minutes. |
|
|
|
|
|
|
|
|
|
|
| D.ZOOM | DZ |
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Super iris ON/super | S | Super iris ON. |
|
|
|
| black ON | B | Super black ON. |
|
|
|
|
|
| |||
|
| SB | Super iris and super black both ON. |
|
| |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Colour temperature | _._K | Colour temperature assigned to A, B, and PRE of the WHITE BAL switch (this is a |
|
|
|
|
|
| value stored at AWB performance or a value set through the menu option). The |
|
|
|
|
|
|
|
| |
|
|
|
| indication is not provided in ATW mode. |
|
|
|
|
|
|
|
|
|
|
| Shutter speed/mode | 1/__._ | Shutter speed set to SYNCHRO SCAN. |
|
|
|
|
|
| |||
|
|
| 1/60 - 1/2000 | Shutter speed fixed. |
|
|
|
|
|
|
| ||
|
|
| SUPER V | Shutter speed set to SUPER V (high vertical resolution mode). |
|
|
|
|
|
|
|
|
|
49